Skip to content
Now offering free shipping on all orders over Kshs 5,000!
Now offering free shipping on orders over Kshs 5,000!

Sick Safety relay: RLY3-EMSS300

Free returns on all eligible orders

You have 30 days to request a return. All sale items are final sale.

Applications Evaluation unit
Compatible sensor types Safety sensors with potential-free outputs

 

  • Safety-related parameters
Safety integrity level SIL 3 (IEC 61508)
Category Category 4 (ISO 13849-1)
Performance level PL e (ISO 13849-1)
PFHD (mean probability of a dangerous failure per hour) 1.0 x 10-9
TM (mission time) 20 years (ISO 13849-1)
Stop category 0 (IEC 60204-1)

 

  • Functions
Sensor monitoring

Discrepancy monitoring

Cross-circuit detection

Restart interlock
Reset

Automatic

Manual

External device monitoring (EDM)

 

  • Interfaces
Connection type Front connector with spring terminals
Inputs

2 safety inputs

1 input for reset pushbutton or external device monitoring (EDM)

Outputs

3 enabling current paths (safe)

2 application diagnostic outputs (not safe)

3 test pulse outputs (not safe)

Display elements LEDs
Configuration method Hard wired

 

  • Electronics
Voltage supply PELV or SELV
Supply voltage VS 24 V DC (16.8 V ... 30 V)
Residual ripple ≤ 2.4 V
Power consumption ≤ 2.5 W (DC)
Safety inputs
Number 2
Input voltage HIGH 24 V DC (11 V ... 30 V)
Input voltage LOW 0 V DC (–3 V ... 5 V)
Input current 4 mA ... 6 mA
Activation time tolerance between the two start buttons ≤ 3 s
Reset pushbutton or external device monitoring (EDM) input
Number 1
Input voltage HIGH 24 V DC (11 V ... 30 V)
Input voltage LOW 0 V DC (–3 V ... 5 V)
Input current 4 mA ... 6 mA
Enabling current paths
Response time (opening of enabling current paths) 12 ms
Number 3
Type of output N/O contacts, positively guided
Contact material Silver alloy, gold flashed
Switching voltage 10 V AC ... 230 V AC
10 V DC ... 230 V DC
Switching current 10 mA ... 6 A
Total current 12 A
Mechanical life 1 x 107 switching cycles
Overvoltage category III (EN 60664-1)
Rated impulse withstand voltage Uimp 6 kV (EN 60664-1)
Application diagnostic outputs
Number 2
Type of output Push-pull semiconductor output, short-circuit protected
Output voltage HIGH ≥ Vs – 3 V
Output voltage LOW ≤ 3 V
Input current (NPN) ≤ 15 mA
Output current (PNP) ≤ 120 mA
Test pulse outputs
Number 3
Type of output PNP semiconductors, short-circuit protected
Output voltage ≥ Vs – 3 V
Test pulse width 2 ms
Test pulse interval 40 ms
  • Mechanics
Dimensions (W x H x D) 18 mm x 124.6 mm x 85.5 mm
Weight 150 g

 

  • Ambient data
Enclosure rating IP20 (IEC 60529)
Ambient operating temperature –25 °C ... +55 °C
Storage temperature –25 °C ... +70 °C
Air humidity ≤ 95 %, Non-condensing
Interference emission According to IEC 61000-6-4
Interference resistance

According to IEC 61326-3-1

According to IEC 61000-6-2

According to IEC 60947-5-1

 

Dimensional drawing EMSS3, LOOP1, MULT1, OSSD3

Shipping information
Returns & warranty
Fast Quotes

Get your quotation within 24 hours

Genuine Brands

Authorised distributor for Fluke, Milwaukee, Sick, RS & more

Technical Support

Expert guidance on products & applications

Large Stock Ready

Quick delivery from our Nairobi warehouse

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare