This earth tester / earth resistance meter is used to measure lightning-arresters or ground connection lightning-arresters for all kind of buildings. earth tester possesses a hermetic case and fulfils all the VDE 0413 safety requirements for the technical service operators. The earth tester is appropriate for measuring ground electrodes, lightning-arresters or little earth resistance systems as well as for measuring power resistance, conductive elements and coupling components.

Modern switching circuits reduce the influences of both pressure and earth resistance of the surrounding earth electrodes. Calibration of the earth tester with the adjoining control mechanism avoids the loss of precision at measuring.

Frequency control of 850 Hz avoids the influence of scattered currents of the net and its harmonic elements. Besides, this tester has a filter incorporated to delete distorted signs. The earth tester is delivered with the factory calibration however it can also have ISO calibration certificate.

 

Characteristics:
– 3 ½ positions LCD display (máx. 1999)
– High accuracy
– Battery indicator / of range superation
– Data Hold
– Safety: IEC-1010-1 y CAT III 300 V
– Very good quality
– Components: checking cables: 15 m of red
cable, 10 m of yellow cable, 5 m of green
cable, ground needles, batteries and user
manual.
– Optional ISO calibration certificate.

 

Measuring earth resistance.

The earth tester is connected with the special ground components introduced on the earth by means of the checking cables. To make accurate measurements with this tester, ground has to be wet, if not ground will be wet. Ground components will be put in a straight line (place the black cable, then the green cable, the yellow one for one ground rod and finally the red cable for the second ground rod). Now everything is ready to connect the earth tester to check the earth connection of your building. This can be also used inside a building to check that water connections with earth work properly. This tester has been developed according to IEC 1010-1 standard and fulfils all the  safety conditions for  control electronic mechanism (CAT III).

Technical specifications
Functions Range Resolution Accuracy
Earth resistance 0 … 19.99/ 0 … 199/
y 0 … 1999 Ω
10/ 100 mΩ / 1 Ω ± 2% + 2 positions
 AC Stress 0 … 200 V AC
50/60 Hz
0,1 V ± 3% + 2 positions
Lower measurement limit. 0.01 Ω
Current of measurement 2 mAeff / rms
Response time aprox. 2.5 s
Measuring quota 4 s
Frequency 820 Hz
Overload range in case of overlaoad, „1“ is shown
Power 6 x 1.5 V batteries
Dimensions 160 x 120 x 65 mm
Weight 560 g
Safety IEC- 1010- 1; EN 61010- 1
instalation category: III
EMV EN 50081- 1; EN 50082- 1
corresp. DIN/ VDE 0413 part 7
Shipping information
Returns & warranty
Fast Quotes

Get your quotation within 24 hours

Genuine Brands

Authorised distributor for Fluke, Milwaukee, Sick, RS & more

Technical Support

Expert guidance on products & applications

Large Stock Ready

Quick delivery from our Nairobi warehouse

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare