{"product_id":"fluke-t5-600-62max-1ac-ii-ir-thermometer-electrical-tester-and-voltage-detector-kit","title":"Fluke T5-600\/62MAX+\/1AC II IR Thermometer, Electrical Tester and Voltage Detector Kit","description":"\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cp\u003e\u003cstrong\u003eFluke T5 Voltage, Continuity and Current Testers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatically measures volts AC and volts DC with precise digital resolution.\u003c\/li\u003e\n\u003cli\u003eDisplays resistance to 1000 Ω.\u003c\/li\u003e\n\u003cli\u003eEasy and accurate OpenJaw™ current measurement.\u003c\/li\u003e\n\u003cli\u003eContinuity beeper.\u003c\/li\u003e\n\u003cli\u003eRugged enough to withstand a 10 ft (3 m) drop.\u003c\/li\u003e\n\u003cli\u003e600 V model.\u003c\/li\u003e\n\u003cli\u003eAuto off mode to conserve battery life.\u003c\/li\u003e\n\u003cli\u003eAC current.\u003c\/li\u003e\n\u003cli\u003eDisplay hold.\u003c\/li\u003e\n\u003cli\u003eAll inputs of the T5-600 are protected to EN61010-1 CAT III 600V. UL, CSA and VDE listed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 62 MAX+. Small in size. Big on toughness.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDust and water-resistant: IP54 rated.\u003c\/li\u003e\n\u003cli\u003eRugged: 3 m (9.8 ft) drop tested.\u003c\/li\u003e\n\u003cli\u003eErgonomically designed: Completely redesigned for a more natural hand fit.\u003c\/li\u003e\n\u003cli\u003eDistance to spot: 12:1.\u003c\/li\u003e\n\u003cli\u003eDual lasers: Identifies area to be measured.\u003c\/li\u003e\n\u003cli\u003eLarge, backlit display: Makes data easier to read, even in dark areas.\u003c\/li\u003e\n\u003cli\u003eC115 Deluxe soft carrying case with shoulder strap.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct overview: Fluke T5-600\/62MAX+\/1AC II IR Thermometer, Electrical Tester and Voltage Detector Kit\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003cp\u003eThis kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use electrical test tools to find out more about the problem.\u003c\/p\u003e\n\u003ch2\u003eSpecifications: Fluke T5-600\/62MAX+\/1AC II IR Thermometer, Electrical Tester and Voltage Detector Kit\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003cp\u003eFluke T5-600 Voltage, Continuity and Current Tester\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12.9 mm (0.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax wire size\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\/0 THHN cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent range AC rms\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 100.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy AC current (50\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3% ± 3 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Response\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAveraging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage range AC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy AC voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% ± 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage range DC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy DC voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ± 1 count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 1000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity beeper threshold\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOn at \u0026lt; 25 Ω, off at \u0026gt; 400 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolts indicator LED threshold\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGuaranteed on by 30 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% to 95% (5°C to 30°C); 0% to 75% (30°C to 40°C);\u003cbr\u003e0% to 45% (40°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDust\/water resistance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 meters max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 x (specified accuracy)\/°C (\u0026lt; 18°C or \u0026gt; 28°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-2-032, IEC61010-2-033: CAT III 600 V, 100 A ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA, TUV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V between any terminal and earth ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30.5 x 51 x 203 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTwo-years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e200 hour zinc chloride, 400 hour alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 x AA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow battery indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent sensor opening\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration cycle\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTest leads\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty, flexible leads rated for 1000 V use.\u003cbr\u003eField replaceable leads terminate in male shrouded banana plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbes\u003c\/td\u003e\n\u003ctd\u003eOne red, one black.\u003cbr\u003eDetachable Slim-Reach™ probe tips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStyles\u003c\/td\u003e\n\u003ctd\u003eTP1 Slim Reach™ test brobes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCAT IV 600 V, CAT III, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V AC rms from earth to ground, in compliance with EN61010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003eFluke 62 MAX+ Infrared Thermometer\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-30°C to 650°C (-22°F to 1202°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±1.0°C or ±1.0% of reading, whichever is greater\u003cbr\u003e-10°C to 0°C: ±2.0\u003cbr\u003e-30°C to -10°C: ±3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResponse time (95%)\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e\u0026lt; 300 ms (95% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral response\u003c\/td\u003e\n\u003ctd\u003e8 to 14 microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity\u003c\/td\u003e\n\u003ctd\u003e0.10 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12:1 (calculated at 90% energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C (0.2°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability of readings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.5% of reading or \u0026lt; ±0.5°C (1°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAA battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 hours with laser and backlight on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePhysical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e255 g (8.99 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 60°C (-4°F to 140°F), (without battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10% to 90% RH non-condensing at 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12,000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 54 per IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration and shock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61326-1:2006 EN 61326-2:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eStandards and agency approval\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 61010-1: 2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser safety\u003c\/td\u003e\n\u003ctd\u003eFDA and EN 60825-1 Class II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hydromatics Limited","offers":[{"title":"Default Title","offer_id":53374079533422,"sku":null,"price":0.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/7812\/1070\/files\/fluket5-600kit.png?v=1772526113","url":"https:\/\/www.hydromaticsea.com\/products\/fluke-t5-600-62max-1ac-ii-ir-thermometer-electrical-tester-and-voltage-detector-kit","provider":"Hydromatics Limited","version":"1.0","type":"link"}