{"product_id":"fluke-705-loop-calibrator","title":"Fluke 705 Loop Calibrator","description":"\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003ePowerful loop calibrator that provides a very cost effective, integrated solution for calibration, repair, and maintenance of milliamp loops\u003c\/li\u003e\n\u003cli\u003eProvides simultaneous mA and % readout for quick, easy interpretation of readings.\u003c\/li\u003e\n\u003cli\u003eDelivers mA accuracy of 0.02%\u003c\/li\u003e\n\u003cli\u003eFeatures push button 25% steps for fast, easy linearity checks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct overview: Fluke 705 Loop Calibrator\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 705 loop calibrator provides a cost-effective, integrated solution for calibrating milliamp loops\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 705 is a cost-effective, integrated solution for calibration, repair and maintenance of milliamp loops. It features a large display and simple, pushbutton interface for ease of use. Plus, it offers the other capabilities you need most to calibrate mA loops including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emA sourcing, simulation and measurement\u003c\/li\u003e\n\u003cli\u003e0.02% accuracy and 0.001 mA resolution\u003c\/li\u003e\n\u003cli\u003eSimultaneous mA and % of span display\u003c\/li\u003e\n\u003cli\u003eSelectable step or ramp outputs\u003c\/li\u003e\n\u003cli\u003e24 V Loop supply with mA measure\u003c\/li\u003e\n\u003cli\u003e0-28 VDC measurement to check Loop Voltage\u003c\/li\u003e\n\u003cli\u003eEasy battery exchange without opening the case\u003c\/li\u003e\n\u003cli\u003eIncludes “span check” for fast confirmation of zero and span.\u003c\/li\u003e\n\u003cli\u003eProvides selectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests.\u003c\/li\u003e\n\u003cli\u003eIncludes a 24 volt internal loop supply, so you can power and read a transmitter at the same time without a DMM.\u003c\/li\u003e\n\u003cli\u003eRuns on a single 9 V battery that is easily changed without breaking the calibration seal\u003c\/li\u003e\n\u003cli\u003eOffers 0 - 20 mA or 4 - 20 mA default start up modes\u003c\/li\u003e\n\u003cli\u003eComes with a protective yellow holster with test lead storage and a three year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAnd you get all of that in a compact case with a separate protective holster and a three year warranty.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"overview-right\"\u003e\n\u003cdiv id=\"fluke-product-display-box-contents\"\u003e\n\u003ch3\u003eWhat's in the box:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 705 Loop Calibrator\u003c\/li\u003e\n\u003cli\u003eC10 protective yellow holster with Flex-Stand™\u003c\/li\u003e\n\u003cli\u003e(1 set) AC70A Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInstruction sheet\u003c\/li\u003e\n\u003cli\u003e(1 pair) TL75 safety-designed test leads\u003c\/li\u003e\n\u003cli\u003eNIST- traceable calibration report and data\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 705 Loop Calibrator\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.02% Rdg + 2 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent sourcing\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA or 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.025% Rdg + 2 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive capability\u003c\/td\u003e\n\u003ctd\u003e1000 Ω @ 24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent simulation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA or 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.025% Rdg + 2 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExt. loop voltage requirement\u003c\/td\u003e\n\u003ctd\u003e12-30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop power\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWhile measuring mA, 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 28 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.025% Rdg + 2 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 90% (0°C to 35°C); 0 to 70% (35°C to 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to 18°C, 28°C to 55°C, ±.005% of range per°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA C22.2 No. 1010.1:1992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN50082-1:1992 and EN55022:1994 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e152 x 70 x 41 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e340 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOne 9 V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock and vibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eper MIL-T-28800 for a Class 2 Instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay current and % of span\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto step, auto ramp\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan check\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hydromatics Limited","offers":[{"title":"Default Title","offer_id":53877817868654,"sku":null,"price":0.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/7812\/1070\/files\/705_72dpi_950x1181px_E_NR-147.jpg?v=1780646705","url":"https:\/\/www.hydromaticsea.com\/products\/fluke-705-loop-calibrator","provider":"Hydromatics Limited","version":"1.0","type":"link"}