{"product_id":"fluke-700g-pressure-gauge-calibrator","title":"Fluke 700G Pressure Gauge Calibrator","description":"\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli data-list-item-id=\"ef66c4480d9b73bbab3e744fa0abc0ce4\"\u003ePrecision pressure gauge calibrators designed for fast, accurate test results\u003c\/li\u003e\n\u003cli data-list-item-id=\"e857e90db31bb864dac727f14bd526594\"\u003eMake precise pressure measurements from ±10 inH2O\/20 mbar to 10,000 psi\/690 bar\u003c\/li\u003e\n\u003cli data-list-item-id=\"e23a7028a00d8df9c654a626ddfc2b14a\"\u003eHighly accurate; 0.05% measurement uncertainty for 1 year\u003c\/li\u003e\n\u003cli data-list-item-id=\"e4f286e6bdabbda888fd5c6a1934e9a7c\"\u003eEasily view in most environments with bright backlit display\u003c\/li\u003e\n\u003cli data-list-item-id=\"e7d53933611d4fc8085188526f00b4165\"\u003eTake your gauge anywhere with a rugged protective holster\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 700G Pressure Gauge Calibrator\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003ctable class=\"table not-trash\"\u003e\n\u003ccaption\u003e700R Ranges: Temperature Compensation 0 e °C to 50 °C (32 °F to 122 °F) to rated accuracy.\u003cbr\u003eFor temperatures from -10 °C to 0 °C and 50 °C to 55 °C, add .005% FS\/ °C\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003cth\u003eBurst Pressure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G01\u003c\/td\u003e\n\u003ctd\u003e-10 to +10 inH\u003csub\u003e2\u003c\/sub\u003eO\u003cbr\u003e-20 mbar to 20 mbar\u003c\/td\u003e\n\u003ctd\u003e0.001 inH\u003csub\u003e2\u003c\/sub\u003eO,\u003cbr\u003e0.001 mbar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.1% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e3 psi,\u003cbr\u003e210 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G02\u003c\/td\u003e\n\u003ctd\u003e-1 to +1 psi,\u003cbr\u003e-70 mbar to 70 mbar\u003c\/td\u003e\n\u003ctd\u003e0.0001 psi,\u003cbr\u003e0.001 mbar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.1% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e5 psi,\u003cbr\u003e350 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G04\u003c\/td\u003e\n\u003ctd\u003e-14 to 15 psi,\u003cbr\u003e-0.97 to 1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e60 psi,\u003cbr\u003e4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G05\u003c\/td\u003e\n\u003ctd\u003e-14 to 30 psi,\u003cbr\u003e-0.97 to 2 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e120 psi,\u003cbr\u003e8 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G06\u003c\/td\u003e\n\u003ctd\u003e-12 to 100 psi,\u003cbr\u003e-0.83 to 6.9 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e400 psi,\u003cbr\u003e26 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G27\u003c\/td\u003e\n\u003ctd\u003e-12 to 300 psi,\u003cbr\u003e-0.83 to 20 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e1200 psi,\u003cbr\u003e80 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G07\u003c\/td\u003e\n\u003ctd\u003e-12 to 500 psi,\u003cbr\u003e-0.83 to 34 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e2000 psi,\u003cbr\u003e138 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G08\u003c\/td\u003e\n\u003ctd\u003e-14 to 1000 psi,\u003cbr\u003e-0.97 to 69 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e4000 psi,\u003cbr\u003e266 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G10\u003c\/td\u003e\n\u003ctd\u003e-14 to 2000 psi,\u003cbr\u003e-.97 bar to 140 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e8000 psi,\u003cbr\u003e550 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G29\u003c\/td\u003e\n\u003ctd\u003e-14 to 3000 psi,\u003cbr\u003e-0.97 to 200 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e10000 psi,\u003cbr\u003e690 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G30\u003c\/td\u003e\n\u003ctd\u003e-14 to 5000 psi,\u003cbr\u003e-0.97 to 340 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e10000 psi,\u003cbr\u003e690 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G31\u003c\/td\u003e\n\u003ctd\u003e-14 to 10000 psi,\u003cbr\u003e-0.97 to 690 bar\u003c\/td\u003e\n\u003ctd\u003e1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e20000 psi,\u003cbr\u003e1035 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700GA4\u003c\/td\u003e\n\u003ctd\u003e0 to 15 psia,\u003cbr\u003e0 to 1 bar absolute\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e60 psi,\u003cbr\u003e4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700GA5\u003c\/td\u003e\n\u003ctd\u003e0 to 30 psia\u003cbr\u003e0 to 2 bar absolute\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e120 psi,\u003cbr\u003e8 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700GA6\u003c\/td\u003e\n\u003ctd\u003e0 to 100 psia,\u003cbr\u003e0 to 6.9 bar absolute\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e400 psi,\u003cbr\u003e27 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700GA27\u003c\/td\u003e\n\u003ctd\u003e0 to 300 psia,\u003cbr\u003e0 to 20 bar absolute\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e1200 psi,\u003cbr\u003e80 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG05\u003c\/td\u003e\n\u003ctd\u003e-14 to +30 psi,\u003cbr\u003e-0.97 to +2 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e90 psi,\u003cbr\u003e6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG06\u003c\/td\u003e\n\u003ctd\u003e-12 to 100 psi,\u003cbr\u003e-0.83 to 6.9 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e400 psi,\u003cbr\u003e27 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG07\u003c\/td\u003e\n\u003ctd\u003e-12 to 500 psi,\u003cbr\u003e-0.83 to 34\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e2000 psi,\u003cbr\u003e138 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG08\u003c\/td\u003e\n\u003ctd\u003e-14 to 1000 psi,\u003cbr\u003e-0.97 to 69 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e4000 psi,\u003cbr\u003e275 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG29\u003c\/td\u003e\n\u003ctd\u003e-14 to 3000 psi,\u003cbr\u003e-0.97 to 200 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e10000 psi,\u003cbr\u003e690 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG30\u003c\/td\u003e\n\u003ctd\u003e-14 to 5000 psi,\u003cbr\u003e-0.97 to 340 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e15000 psi,\u003cbr\u003e1035 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG31\u003c\/td\u003e\n\u003ctd\u003e-14 to 10000 psi,\u003cbr\u003e-0.97 to 690 bar\u003c\/td\u003e\n\u003ctd\u003e1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e20000 psi,\u003cbr\u003e1380 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table not-trash\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMedia compatibility\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli data-list-item-id=\"eebfd7218b7fd7563135752d66eaba8bc\"\u003e10 inH\u003csub\u003e2\u003c\/sub\u003eO, 1, 15, 30 psi: any clean dry non-corrosive gas\u003c\/li\u003e\n\u003cli data-list-item-id=\"e52b8bbb48d3c0291e5f19307c8361ab6\"\u003e100, 300, 500, 1000 psi: any liquids or gases compatible with 316 stainless steel and above 1000 psi: any non-flammable, non-toxic, non-explosive, non-oxidizing liquid or gas compatible with 316 stainless steel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table not-trash\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eMechanical Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e12.7 x 11.4 x 3.7 cm (5 x 4.5 x 1.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure connection\u003c\/td\u003e\n\u003ctd\u003e¼ in NPT Male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\/Weight\u003c\/td\u003e\n\u003ctd\u003eCast ZNAL 0.56 kg (1.22 lb) with holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5-1\/2 digits, 16.53 mm (0.65 in) high 20-segment bar graph, 0 to 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eThree (3) AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e1,500 hours without backlight (continuous on), 2,000 hours at slow sample rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hydromatics Limited","offers":[{"title":"Default Title","offer_id":53877799715182,"sku":null,"price":0.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/7812\/1070\/files\/FlukePrecisionPressureTestGauges_72dpi_943x1024px_E_NR-13087.jpg?v=1780645668","url":"https:\/\/www.hydromaticsea.com\/products\/fluke-700g-pressure-gauge-calibrator","provider":"Hydromatics Limited","version":"1.0","type":"link"}