{"product_id":"fluke-360-ac-leakage-current-clamp-meter","title":"Fluke 360 AC Leakage Current Clamp Meter","description":"\u003cp\u003e\u003cstrong\u003eThe Fluke 360 leakage tester is a rugged and accurate solution for leakage current measurement.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIdeally designed for non-invasive checks of insulation condition, the Fluke 360 leakage meter allows you to perform tests without powering down the installation or disconnecting equipment - saving you time, without compromising on quality or safety.\u003c\/p\u003e\n\u003cp\u003eThe unique jaw design of the Fluke 360 AC Leakage Current Clamp Meter eliminates the influence of adjacent current conductors, and minimizes the effects of external magnetic fields, even at low currents. This allows you to perform accurate and reliable tests in today?s crowded electrical environments. The tough and high-quality jaw design of the Fluke 360 leakage tester guarantees high stability for long-term repeatability and durability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecial Features.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61010 and EMC Conformance.\u003c\/strong\u003e\u003cbr\u003eIEC 61010 safety features including a tactile barrier and special jaw design provide the user with confidence when making measurements in hazardous voltage areas. Conformance to EMC standards ensures high reliability through reduced susceptibility to electromagnetic interference. The Fluke 360 also meets the latest safety standard VDE0404-4 and the new VDE0702 requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Accuracy.\u003c\/strong\u003e\u003cbr\u003eAdvanced jaw design means that the Fluke 360 accuracy is little affected by external magnetic fields even at low currents. Typical external current rejection is 200,000:1.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy leakage current testing?\u003c\/strong\u003e\u003cbr\u003eLeakage currents can be an indicator of the effectiveness of insulation on conductors. High levels of leakage current may be present in circuits where either the insulation resistance is low, or electronic equipment with filters is used. Leakage currents can cause disruptions of the normal operation of equipment and installations. It is possible to locate the source of leakage currents by using the Fluke 360 leakage current clamp meter and taking methodical measurements throughout the installation. The big advantage of leakage current testing versus insulation testing is that the installation and equipment do not need to be powered down but can be done during normal operation.\u003c\/p\u003e\n\u003ch3 class=\"highlight-heading product-section-heading expand-description\"\u003eIn The Box\u003c\/h3\u003e\n\u003cdiv class=\"hidden hidden-description\"\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 360 AC Current Clamp Meter\u003c\/li\u003e\n\u003cli\u003eSoft carrying pouch\u003c\/li\u003e\n\u003cli\u003eUser's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tech-specs\" class=\"product-specs sn-anchor module-section-1\" data-tabtext=\"Tech Specs\"\u003e\n\u003cdiv class=\"hidden hidden-description\"\u003e\n\u003cdiv\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" class=\"spectable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccellheader\" colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eMethod of detection\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003eMean value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\" rowspan=\"2\" width=\"30%\"\u003eDisplay\u003c\/td\u003e\n\u003ctd class=\"speccelltitle\" width=\"30%\"\u003eDigital display:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e3200 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eBar-graph display:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e32 segments, LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eMeasurement Cycle\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003e2 times\/second (Digital display), 12 times\/second (Bar-graph display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eRange switching\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003eAuto-range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eAmbient temperature and humidity\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003e0 °C to 50 °C, 80 % R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eor less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003e0.05% of range\/°C or less (within the ranges of 0 °C to 18 °C and 28 °C to 50 °C for measurement of 0-50 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eInfluence of external magnetic field\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003e0.0005% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eInfluence of conductor position\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003eWithin accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eCircuit voltage\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003e\u0026lt;300 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eSafety standard\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003eEN 61010-1, EN 61010-2-032, 300 V CAT III, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eWithstanding voltage\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003e3.7 kV ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eBattery type\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003e1 x 3 V Lithium battery (button cell) CR2032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eBattery life\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003eApprox. 90 hours (when continuously used)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eAuto power-off\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003eApprox. 10 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eDiameter of measurable conductor\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003e40 mm max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eDimension\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003e176 mm x 70 mm x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd class=\"speccelldata\" colspan=\"2\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" class=\"spectable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccellheader\" colspan=\"3\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\" rowspan=\"3\" width=\"30%\"\u003e3 mA\u003c\/td\u003e\n\u003ctd class=\"speccelltitle\" width=\"30%\"\u003eResolution:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e0.001 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eAccuracy:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e1% + 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eMax Permissible current:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e60 A rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\" rowspan=\"3\"\u003e30 mA\u003c\/td\u003e\n\u003ctd class=\"speccelltitle\"\u003eResolution:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eAccuracy:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e1% + 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eMax Permissible current:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e60 A rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\" rowspan=\"3\"\u003e30 A\u003c\/td\u003e\n\u003ctd class=\"speccelltitle\"\u003eResolution:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e0.01 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eAccuracy:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e1% + 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eMax Permissible current:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e60 A rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\" rowspan=\"3\"\u003e60 A\u003c\/td\u003e\n\u003ctd class=\"speccelltitle\"\u003eResolution:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eAccuracy:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e5% + 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eMax Permissible current:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e60 A rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"speccelltitle\"\u003eMean value detection and rms-value calibration\u003c\/td\u003e\n\u003ctd class=\"speccelltitle\"\u003eAccuracy specified at:\u003c\/td\u003e\n\u003ctd class=\"speccelldata\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-specs sn-anchor module-section-1\"\u003e\n\u003ch3 class=\"highlight-heading expand-description\"\u003eTech Specs\u003c\/h3\u003e\n\u003ctable class=\"compTbl table table-hover hidden hidden-description\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"spanhdr\"\u003e\n\u003cth colspan=\"2\" scope=\"col\"\u003e\n\u003ch4\u003eClamp Meters\/Clamp Meters Template\u003c\/h4\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca\u003eTrue RMS\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca\u003eMaximum Current AC\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003e60 A\u003cspan class=\"toolTipTrigger\"\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResistance\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCapacitance\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca\u003eAuto Ranging\/Manual\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003eAuto Ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca\u003eIn-Rush Current\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Hydromatics Limited","offers":[{"title":"Default Title","offer_id":53308270903662,"sku":null,"price":0.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/7812\/1070\/files\/360_image_1.jpg?v=1771230957","url":"https:\/\/www.hydromaticsea.com\/products\/fluke-360-ac-leakage-current-clamp-meter","provider":"Hydromatics Limited","version":"1.0","type":"link"}