{"product_id":"fluke-355-true-rms-2000-a-clamp-meter","title":"Fluke 355 True RMS 2000 A Clamp Meter","description":"\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eReliably handle a wide range of high-current applications with 2000 A AC + DC True RMS, 1400 A AC, and 2000 A DC\u003c\/li\u003e\n\u003cli\u003eThe large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V rating for added user protection\u003c\/li\u003e\n\u003cli\u003eIn-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct overview: Fluke 355 True RMS 2000 A Clamp Meter\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003ch2\u003eVersatile and rugged clamp meter for high currents\u003c\/h2\u003e\n\u003cp\u003eConfidently take reliable readings with the True RMS Fluke 355 digital clamp meter, the tool of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.\u003c\/p\u003e\n\u003cp\u003eAccurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.\u003c\/p\u003e\n\u003ch2\u003eEasy to use all-in-one tool\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh voltage measurement of 1000 V AC + DC True RMS, 600 V AC, and 1000 V DC allows the user to perform multiple tests with only one tool\u003c\/li\u003e\n\u003cli\u003eResistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter\u003c\/li\u003e\n\u003cli\u003eAccurately measure frequency up to 1 kHz for optimum troubleshooting\u003c\/li\u003e\n\u003cli\u003eQuickly analyze readings using the MIN, MAX, and AVG functions\u003c\/li\u003e\n\u003cli\u003eA large backlit display allows for easy visibility in low-lit areas\u003c\/li\u003e\n\u003cli\u003eUse the display hold feature to capture readings even when the display cannot be viewed\u003c\/li\u003e\n\u003cli\u003eUse the low-pass filter to smooth out noisy loads and stabilize readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct overview: Fluke 355 True RMS 2000 A Clamp Meter\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003ch2\u003eVersatile and rugged clamp meter for high currents\u003c\/h2\u003e\n\u003cp\u003eConfidently take reliable readings with the True RMS Fluke 355 digital clamp meter, the tool of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.\u003c\/p\u003e\n\u003cp\u003eAccurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.\u003c\/p\u003e\n\u003ch2\u003eEasy to use all-in-one tool\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh voltage measurement of 1000 V AC + DC True RMS, 600 V AC, and 1000 V DC allows the user to perform multiple tests with only one tool\u003c\/li\u003e\n\u003cli\u003eResistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter\u003c\/li\u003e\n\u003cli\u003eAccurately measure frequency up to 1 kHz for optimum troubleshooting\u003c\/li\u003e\n\u003cli\u003eQuickly analyze readings using the MIN, MAX, and AVG functions\u003c\/li\u003e\n\u003cli\u003eA large backlit display allows for easy visibility in low-lit areas\u003c\/li\u003e\n\u003cli\u003eUse the display hold feature to capture readings even when the display cannot be viewed\u003c\/li\u003e\n\u003cli\u003eUse the low-pass filter to smooth out noisy loads and stabilize readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 355 True RMS 2000 A Clamp Meter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\" width=\"25%\"\u003eCurrent measurement AC 10 Hz to 100 Hz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A \/ 400 A \/ 1400 AC rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e10 mA \/ 100 mA \/ 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e40 A: 1.5% rdg + 15 digits \u003cbr\u003e400 A: 1.5% rdg + 5 digits \u003cbr\u003e1400 A: 1.5% rdg + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Inrush\u003c\/td\u003e\n\u003ctd\u003e0.50 A \/ 5.0 A \/ 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Hz filter OFF\u003c\/td\u003e\n\u003ctd\u003e2.50 A \/ 2.5 A \/ 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Hz filter ON\u003c\/td\u003e\n\u003ctd\u003e0.50 A \/ 2.5 A \/ 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A \/ 400 A \/ 1400 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2 @ 33 A, 2.4 @ 27 A\u003cbr\u003e2 @ 330 A, 2.4 @ 270 A\u003cbr\u003e2 @ 1000 A, 2.4 @ 833 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eCurrent measurement AC 100.1 Hz to 1 kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A \/ 400 A \/ 1400 AC rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e10 mA \/ 100 mA \/ 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e40 A: 3.5% rdg + 15 digits \u003cbr\u003e400 A: 3.5% rdg + 5 digits \u003cbr\u003e1400 A: 3.5% rdg + 5 digits \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Inrush\u003c\/td\u003e\n\u003ctd\u003e0.50 A \/ 5.0 A \/ 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Hz filter OFF\u003c\/td\u003e\n\u003ctd\u003e2.50 A \/ 2.5 A \/ 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Hz filter ON\u003c\/td\u003e\n\u003ctd\u003e0.50 A \/ 2.5 A \/ 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent measurement DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A \/ 400 A \/ 2000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 A \/ 0.1 A \/ 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e40 A: 1.5% rdg + 15 digits \u003cbr\u003e400 A: 1.5% rdg + 5 digits \u003cbr\u003e2000 A: 1.5% rdg + 5 digits \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eVoltage measurement AC 10 Hz to 100 Hz\u003cbr\u003e(600 V range has 10% over range to 660 V)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 V \/ 40 V \/ 400 V \/ 600 V AC rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV \/ 10 mV \/ 100 mV \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e4 V: 1% rdg + 10 digits \u003cbr\u003e40 V: 1% rdg + 5 digits \u003cbr\u003e400 V: 1% rdg + 5 digits \u003cbr\u003e600 V: 1% rdg + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Hz filter OFF\u003c\/td\u003e\n\u003ctd\u003e0.25 V \/ 6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Hz filter ON\u003c\/td\u003e\n\u003ctd\u003e0.25 V \/ 6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eVoltage measurement AC 100.1 Hz to 1 kHz\u003cbr\u003e(600 V range has 10% over range to 660 V)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 V \/ 40 V \/ 400 V \/ 600 V ac rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV \/ 10 mV \/ 100 mV \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e4 V: 3% rdg + 10 digits \u003cbr\u003e40 V: 3% rdg + 5 digits \u003cbr\u003e400 V: 3% rdg + 5 digits \u003cbr\u003e600 V: 3% rdg + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Hz filter OFF\u003c\/td\u003e\n\u003ctd\u003e0.050 V \/ 0.25 V \/ 6 V \/ 6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Hz filter ON\u003c\/td\u003e\n\u003ctd\u003e0.050 V \/ 0.25 V \/ 6 V \/ 6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage measurement DC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 V \/ 40 V \/ 400 V \/ 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 V \/ 0.01 V \/ 0.1 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e4 V: 1% rdg + 10 digits \u003cbr\u003e40 V: 1% rdg + 5 digits \u003cbr\u003e400 V: 1% rdg + 5 digits \u003cbr\u003e1000 V: 1% rdg + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResistance measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 Ω \/ 4 kΩ \/ 40 kΩ \/ 400 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω \/ 1 Ω \/ 10 Ω \/ 100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity beeper\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOn at ≤ 30 Ω\u003cbr\u003eOff at ≥ 100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eFrequency measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 Hz to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy – 5.0 Hz to 100 Hz\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy – 100.1 Hz to 1 kHz\u003c\/td\u003e\n\u003ctd\u003e0.5% + 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level\u003c\/td\u003e\n\u003ctd\u003eRefer to current and voltage tables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003e1. Add 2% to error spec for CF \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSix 1.5 V AA NEDA 15 A or IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life (with typical usage, backlight off)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e100 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest leads\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRated to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e.814 kg (1.8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw size\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e58 mm (2.28 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e300 x 98 x 52 mm (12 x 3.75 x 2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-2-032, 600 V CAT IV, 1000 V CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32°F to +122°F (0°C to +50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-4°F to 140°F (-20°C to +60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e42 (indoor use only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test requirements\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFCC part 15, IEC\/EN 61326-1:1997 class B\u003cbr\u003eIEC\/EN 61326:1997 3 V\/m, performance criteria B, EN61325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature coefficients\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1% of reading per °C outside 22°C to 24°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e0.1% of reading per °C outside 22°C to 24°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hydromatics Limited","offers":[{"title":"Default Title","offer_id":53308270018926,"sku":null,"price":0.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/7812\/1070\/files\/fluke355.png?v=1771230553","url":"https:\/\/www.hydromaticsea.com\/products\/fluke-355-true-rms-2000-a-clamp-meter","provider":"Hydromatics Limited","version":"1.0","type":"link"}