{"product_id":"fluke-289-flukeview®-forms-combo-kit","title":"Fluke 289 FlukeView® Forms Combo Kit","description":"\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cp\u003e\u003cstrong\u003eEquipped with new functionality\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNEW – Now compatible with Fluke Connect mobile app and all Fluke FC enabled test tools with optional ir3000 FC infrared connector (sold separately).\u003c\/li\u003e\n\u003cli\u003eNEW – Let your team see what you see in an instant with ShareLive™ video call (requires Fluke Connect mobile app and ir3000 FC wireless connector).\u003c\/li\u003e\n\u003cli\u003eTrendCapture graphically displays logged data session to quickly determine whether anomalies may have occurred. \u003c\/li\u003e\n\u003cli\u003eZoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times.\u003c\/li\u003e\n\u003cli\u003eSelectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy.\u003c\/li\u003e\n\u003cli\u003eAdjustable recording and auto hold thresholds, specify a percentage change in the readings that begins a new event.\u003c\/li\u003e\n\u003cli\u003eLarge 50,000 count, 1\/4 VGA dot matrix display with white backlight.\u003c\/li\u003e\n\u003cli\u003eLogging function with expanded memory for unattended monitoring of signals over time. Using on-board TrendCapture users can graphically review logged readings without needing a PC. Store up to 15,000 recorded events.\u003c\/li\u003e\n\u003cli\u003eSave multiple logging sessions before PC download is necessary.\u003c\/li\u003e\n\u003cli\u003eTwo terminal 50 ohm range with 1 milliohm resolution, 10 mA source current. Useful for measuring and comparing differences in motor winding resistance or contact resistance.\u003c\/li\u003e\n\u003cli\u003eLow Pass filter for accurate voltage and frequency measurements at the same time on adjustable speed motor drives and other electrically noisy equipment.\u003c\/li\u003e\n\u003cli\u003eLoZ Volts. Low impedance voltage function for eliminating ghost voltages. Also recommended when testing for absence or presence of live power.\u003c\/li\u003e\n\u003cli\u003eOn board help screens for measurement functions. Unsure about a function - go to that function and press the \"i\" button.\u003c\/li\u003e\n\u003cli\u003eReal time clock for automatic time stamping of saved readings.\u003c\/li\u003e\n\u003cli\u003eRelative mode to remove test lead resistance from low ohms or capacitance measurements.\u003c\/li\u003e\n\u003cli\u003eTrue-RMS AC voltage and current for accurate measurements on non-linear signals.\u003c\/li\u003e\n\u003cli\u003eMeasure up to 10 A (20 A for 30 seconds).\u003c\/li\u003e\n\u003cli\u003e100 mF capacitance range.\u003c\/li\u003e\n\u003cli\u003ePeak capture to record transients as fast as 250 μs.\u003c\/li\u003e\n\u003cli\u003ePremium test leads and alligator clips included.\u003c\/li\u003e\n\u003cli\u003eAmp jack plugs included.\u003c\/li\u003e\n\u003cli\u003eOptional magnetic hanger for easy setup and viewing while freeing your hands for other tasks.\u003c\/li\u003e\n\u003cli\u003eFlukeView forms enable you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents.\u003c\/li\u003e\n\u003cli\u003eLimited lifetime warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct overview: Fluke 289 FlukeView® Forms Combo Kit\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003cp\u003e\u003cstrong\u003eNow compatible with Fluke Connect® Mobile App\u003c\/strong\u003e\u003cbr\u003eMaximize productivity with the combined Fluke 289 and FlukeView® Forms Combo Kit. With built-in data logger and TrendCapture capability, the 289 helps you track down elusive, intermittent problems, monitoring equipment with any of its functions while you do other jobs. Using FlukeView Forms software allows you to overlay your logged data from six meters or six time periods to find cause and affect relationships or for condition monitoring. Turn your data into meaningful graphs and tables for a professional report or analyze individual readings or series of measurements.\u003c\/p\u003e\n\u003cp\u003eThe 289 is compatible with the Fluke ir3000 FC Infrared Connector, allowing you to share live measurements on your iOS or Android smart device with the Fluke Connect mobile app. The 289\/FVF combo kit gives you a practical and affordable approach to predictive maintenance.\u003c\/p\u003e\n\u003ch2\u003eSpecifications: Fluke 289 FlukeView® Forms Combo Kit\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eFunction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC volts\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \/ resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic accuracy\u003c\/td\u003e\n\u003ctd\u003e0.025%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC volts\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \/ resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic accuracy\u003c\/td\u003e\n\u003ctd\u003e0.4% (True-RMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC current\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \/ resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic accuracy\u003c\/td\u003e\n\u003ctd\u003e0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC current\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \/ resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic accuracy\u003c\/td\u003e\n\u003ctd\u003e0.6% (True-RMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature (excluding probe)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \/ resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-200.0°C to 1350.0°C (-328.0°F to 2462.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic accuracy\u003c\/td\u003e\n\u003ctd\u003e1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \/ resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic accuracy\u003c\/td\u003e\n\u003ctd\u003e0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \/ resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.000 nF,10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic accuracy\u003c\/td\u003e\n\u003ctd\u003e1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \/ resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic accuracy\u003c\/td\u003e\n\u003ctd\u003e0.005%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOptional infrared connector via Fluke ir3000 FC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6 AA alkaline batteries, NEDA 15A IECLR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e100 hours minimum, 200 hours in logging mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 90% (0 to 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEMC EN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom vibration per MIL-PRF-28800F Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop per IEC\/EN 61010-1 3rd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e870.9 g (28 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiple on screen displays\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue-RMS AC bandwidth\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edBV\/dBm\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC mV resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMegohm range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUp to 500 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50.00 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity beeper\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\/fuse access\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\/Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElapse time clock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime of day clock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin-max-avg\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty cycle\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse width\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolated optical interface\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto\/touch hold\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog to PC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterval\/event logging\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUp to 15,000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless connectivity (optional)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hydromatics Limited","offers":[{"title":"Default Title","offer_id":53291033428334,"sku":null,"price":0.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/7812\/1070\/files\/fluke289FVF.png?v=1770637543","url":"https:\/\/www.hydromaticsea.com\/products\/fluke-289-flukeview%c2%ae-forms-combo-kit","provider":"Hydromatics Limited","version":"1.0","type":"link"}