{"product_id":"fluke-283-fc-pv-solar-digital-multimeter-and-wireless-current-clamp","title":"Fluke 283 FC\/PV Solar Digital Multimeter and Wireless Current Clamp","description":"\u003ch2 class=\"features-title\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eCAT III 1500 V\/CAT IV 1000 V safety rated multimeter, wireless current clamp and test leads\u003c\/li\u003e\n\u003cli\u003eIncludes CAT III 1500 V rated Staubli MC4 MC4 test leads\u003c\/li\u003e\n\u003cli\u003eUser-defined limit gauge for quick go\/no-go decisions\u003c\/li\u003e\n\u003cli\u003eUnique multimeter readiness self-check\u003c\/li\u003e\n\u003cli\u003eVisual and audio polarity indicators with on\/off function wiring issues\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct overview: Fluke 283 FC\/PV Solar Digital Multimeter and Wireless Current Clamp\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003cp\u003e\u003cstrong\u003eUnmatched safety and convenience for solar professionals\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CAT III 1500 V\/CAT IV 1000 V True-RMS Fluke 283 FC Digital Multimeter and a283 FC True-RMS Wireless Current Clamp set the new standard for technicians in DC environments up to 1500 V. Whether you’re working with a utility-scale solar photovoltaic (PV) array, wind power, an electric railway, or a data center, the Fluke 283 FC has been engineered to enhance safety and increase productivity while giving you accurate, reliable, and repeatable results.\u003c\/p\u003e\n\u003cp\u003eThe 283 FC\/PV includes CAT III 1500 V DC safety-rated accessories so you can work confidently in higher voltage environments without compromising safety. Staubli MC4 test leads allow you to quickly make reliable, secure connections to modules or strings to test DC voltage up to 1500 V DC. TL175-HV CAT III 1500 V\/CAT IV 1000 V rated silicone test leads give you more flexibility when testing voltage, millivoltage, resistance, continuity, or capacitance on inverters, combiner boxes, PV arrays, or individual PV modules. A bright backlit LCD screen and illuminated keypad make it easier to work in both direct and low light conditions. The included magnetic hanging kit frees up your hands and the custom hard carrying case protects your investment while you transport it.\u003c\/p\u003e\n\u003cp\u003eAdditional features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHighly accurate voltage measurements for precise frontline troubleshooting\u003c\/li\u003e\n\u003cli\u003eCurrent measurements up to 60 A AC\/DC for safely troubleshooting individual strings of modules with greater accuracy (when using a283 FC wireless current clamp)\u003c\/li\u003e\n\u003cli\u003eVisual and audio polarity indicators help prevent accidental module wiring issues\u003c\/li\u003e\n\u003cli\u003eUser-defined limit gauge helps you make quick go\/no-go troubleshooting decisions\u003c\/li\u003e\n\u003cli\u003eUnique multimeter readiness self-check helps ensure your meter is ready to test\u003c\/li\u003e\n\u003cli\u003eSave and log measurements to internal memory and view them on your mobile device via Fluke Connect™\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCAT III 1500 V \/ CAT IV 1000 V Safety Rated\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCAT III 1500 V DC systems are now a standard in utility scale PV systems, offering significant cost savings and efficiency improvements to facility owners. These systems operate at higher voltage levels, allowing each inverter to handle more energy, enable longer strings of connected panels, and reduce the need for additional wiring and inverters. Consequently, standard CAT IV inverter outputs of 800 V AC or higher are more prevalent, making it crucial to prioritize safety and accuracy in measurements.\u003c\/p\u003e\n\u003cp\u003eThe CAT III 1500 V \/ CAT IV 1000 V rated 283 FC multimeter and a283 FC wireless current clamp meet the safety requirements for test equipment (IEC 61010-2-032) corresponding to the overvoltage category level of the PV array electrical installation (IEC 61730-1). Combine these with CAT III 1500 V \/ CAT IV 1000 V rated TL175-HV Premium Silicone Test Leads, CAT III 1500 V MC4 connectors and you’ve got a comprehensive frontline troubleshooting solution that offers safe and accurate voltage measurement for troubleshooting everything from the inverters, combiners, strings of modules, or individual modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser-Defined Limit Gauge\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOn large-scale PV projects where you’re taking repetitive measurements and expect consistent results, the user-defined limit gauge becomes a vital time-saving tool. The adjustable limit gauge can trigger audio and visual indications whenever a measurement falls outside your expected range. This saves you time letting you quickly evaluate measurement results, increasing your confidence in the system's performance, and helping to identify potential issues that need to be addressed.\u003c\/p\u003e\n\u003cp\u003eWith the dedicated limit gauge button, you can easily turn the limit gauge warnings on and off, set up new measurement parameters, or select from previously used parameter profiles. This customization streamlines troubleshooting, allowing you to quickly identify measurement deviations or errors, and helps maintain optimum solar installation performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUnique Multimeter Readiness Self-Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe size and location of utility-scale solar sites can present unique challenges whether they’re logistical, environmental, or testing related. Because of that, you want to have confidence that your meter is fully functional, capturing the right data every time so you don’t have to do the same job twice. The 283 FC features a unique integrated multimeter readiness self-check, that ensures your meter is in proper working order before you take your next reading. This quick self-check is an additional readiness test that gives you valuable insight to the status of your meter’s calibration, battery life availability, test lead functionality, and AC\/DC voltage measurement functionality so you can be confident that your meter is ready to work when you are.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWireless Current Clamp\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe a283 FC True-RMS wireless current clamp is designed to simplify the troubleshooting process without compromising on safety and reliability. It can measure both AC and DC current up to 60 A, ensuring precise and reliable readings for a wide range of applications including solar installations, electrical systems, and industrial equipment. With its non-contact design, the clamp allows for safe connections without the need to touch live wires, enabling you to close the clamp in a cabinet and take measurements from a safe distance. It carries a CAT III 1500 V, CAT IV 1000 V rating that matches the safety rating of the 283 FC.\u003c\/p\u003e\n\u003cp\u003eWireless connectivity allows for convenient transmission of measurements, eliminating the hassle of tangled wires and allowing you to install the current clamp in an enclosure so you can safely measure at a distance. The clamp has a thin jaw design to ensure easy access to combiner boxes and tight spaces, enhancing overall efficiency in your measurement process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage and Current at the same time\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith the 283 FC digital multimeter and a283 FC wireless current clamp, you can measure voltage and current at the same time and automatically calculate VA power. This eliminates the hassle of having to change your measurement setup to capture both measurements and eliminates the need to manually calculate power in the field. Voltage and current are time-stamped, eliminating any concerns about potential disparities being caused by environmental factors. You can also view more than one measurement at a time allowing you to monitor additional parameters like DC amperage or voltage, giving you even more insights into system performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLogging \/ saving\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 283 FC offers convenient logging and saving features that set it apart from other digital multimeters. With a built-in real-time clock, each measurement can be time- and date-stamped for accurate recordkeeping. The multimeter has internal memory to save and log measurements, which can then be easily transferred to Fluke Connect for further analysis. Additionally, you have the flexibility to customize logging durations and intervals, ensuring the logging process matches the specific needs of the system you are testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluke Connect™ with Fluke Cloud™ Storage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFluke Connect™ compatibility provides convenient features to enhance your troubleshooting experience. As part of the Fluke Connect family, the 283 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. No need to write down the results. Trend and monitor measurements live on your phone screen and upload those measurements to the cloud. Combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email and collaborate in real time with other colleagues with ShareLive™ video calls or email. The table view feature organizes measurements, notes, and images in a clear and efficient manner, making it easier to reference data, identify issues, and generate reports for customers. Fluke Connect™ with Fluke Cloud™ Storage streamlines your workflow and ensures accurate data storage and organization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"overview-right\"\u003e\n\u003cdiv id=\"fluke-product-display-box-contents\"\u003e\n\u003ch3\u003eWhat's in the box:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e283 FC TRMS Wireless Digital Multimeter\u003c\/li\u003e\n\u003cli\u003ea283 FC 60A TRMS Wireless AC\/DC Current Clamp\u003c\/li\u003e\n\u003cli\u003eSolar MC4 test Lead set\u003c\/li\u003e\n\u003cli\u003eTL175-HV TwistGuard™ Silicone test leads\u003c\/li\u003e\n\u003cli\u003ePremium carrying case\u003c\/li\u003e\n\u003cli\u003eMagnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eLimited Lifetime Warranty on the multimeter\u003c\/li\u003e\n\u003cli\u003e1-year warranty on the clamp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 283 FC\/PV Solar Digital Multimeter and Wireless Current Clamp\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003ch3\u003e283 FC Digital Multimeter\u003c\/h3\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAC volts\u003csup\u003e[1]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e6.000 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e1.0 % + 3\u003cbr\u003e(45 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60.00 V\u003c\/td\u003e\n\u003ctd\u003e0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e2.0 % + 3\u003cbr\u003e(500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eDC volts\u003c\/td\u003e\n\u003ctd\u003e6.000 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e0.09 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60.00 V\u003c\/td\u003e\n\u003ctd\u003e0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1500 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e0.15 % + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC mV\u003csup\u003e[1]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e600.0 mV\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (45 Hz ~ 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz ~ 1000 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC mV\u003c\/td\u003e\n\u003ctd\u003e600.0 mV\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e0.09 % + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e600 Ω\u003c\/td\u003e\n\u003ctd\u003e1 Ω\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd rowspan=\"5\"\u003e0.5 % + 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6.000 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.001 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600.0 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6.000 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.001 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50.00 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e1.5 % + 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1000 nF\u003c\/td\u003e\n\u003ctd\u003e1 nF\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e1.2 % + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10.00 μF\u003c\/td\u003e\n\u003ctd\u003e0.01 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100.0 μF\u003c\/td\u003e\n\u003ctd\u003e0.1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9999 μF\u003c\/td\u003e\n\u003ctd\u003e1 μF\u003c\/td\u003e\n\u003ctd\u003e10 % typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e99.99 Hz\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e0.1 % + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e999.9 Hz\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9.999 kHz\u003c\/td\u003e\n\u003ctd\u003e0.001 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e99.99 kHz\u003c\/td\u003e\n\u003ctd\u003e0.01 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAC VA (45~500Hz)\u003csup\u003e[1]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e360.0 VA\u003c\/td\u003e\n\u003ctd\u003e0.1 VA\u003c\/td\u003e\n\u003ctd\u003e2 % + 1.0 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3.600 kVA\u003c\/td\u003e\n\u003ctd\u003e0.001 kVA\u003c\/td\u003e\n\u003ctd\u003e2 % + 0.01 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e36.00 kVA\u003c\/td\u003e\n\u003ctd\u003e0.01 kVA\u003c\/td\u003e\n\u003ctd\u003e2 % + 0.1 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60.00 kVA\u003c\/td\u003e\n\u003ctd\u003e0.01 kVA\u003c\/td\u003e\n\u003ctd\u003e2 % + 0.15 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eDC VA\u003csup\u003e[1]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e360.0 VA\u003c\/td\u003e\n\u003ctd\u003e0.1 VA\u003c\/td\u003e\n\u003ctd\u003e2 % + 1.0 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3.600 kVA\u003c\/td\u003e\n\u003ctd\u003e0.001 kVA\u003c\/td\u003e\n\u003ctd\u003e2 % + 0.01 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e36.00 kVA\u003c\/td\u003e\n\u003ctd\u003e0.01 kVA\u003c\/td\u003e\n\u003ctd\u003e2 % + 0.1 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e90.00 kVA\u003c\/td\u003e\n\u003ctd\u003e0.01 kVA\u003c\/td\u003e\n\u003ctd\u003e2 % + 0.25 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMin-max avg\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eFor DC functions, accuracy is the specified accuracy of the measurement function ± 12 counts for changes longer than 350 ms in duration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eFor AC functions, accuracy is the specified accuracy of the measurement function ± 40 counts for changes longer than 900 ms in duration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csup\u003e[1]\u003c\/sup\u003e \u0026lt;1% range, unspecified\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eEnvironmental specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-30 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd\u003e0 % to 90 %, 10 °C to 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 % to 75 %, 30 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 % to 45 %, 40 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eWarranty and Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1, IEC 61326-2-2, Portable, Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eCAT III 1500 V, CAT IV 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd\u003eETL (AMER and EMEA), CSA (APAC), CE, UK CA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd\u003e2 meter (6.5 ft) drop test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited lifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMechanical and general specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounts\u003c\/td\u003e\n\u003ctd\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e22.5 cm x 10.5 cm x 5.7 cm (8.8 in x 4.1 in x 2.2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg (1.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 150 hours typical, without backlight (Alkaline, 3 AA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt; 100 hours typical when connected to wireless current clamp (Alkaline, 3 AA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003ea283 FC Wireless Current Clamp\u003c\/h3\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current (True-RMS)\u003csup\u003e[2]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003ctd\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e1.5% + 0.15 A, 45～500Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC current\u003csup\u003e[2]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003ctd\u003e0.01 A \u003c\/td\u003e\n\u003ctd\u003e1.5% + 0.15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral specifications – Fluke a283 FC Wireless Current Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-30 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd\u003e0 % to 90 %, 5 °C to 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 % to 75 %, 30 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 % to 45 %, 40 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eWarranty and Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1, IEC 61326-2-2, Portable, Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eCAT III 1500 V, CAT IV 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd\u003eETL (AMER and EMEA), CSA (APAC), CE, UK CA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd\u003e2 meter (6.5 ft) drop test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e1-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMechanical and general specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e226.0 mm x 91.0 mm x 42.0 mm (8.9 in x 3.6 in x 1.7 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd\u003e34 mm (1.34 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.375 kg (13.2 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 hours typical (Alkaline, 2 AAA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFeatures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED indicator\u003c\/td\u003e\n\u003ctd\u003eIndicates wireless connection and data transmission status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery indicator\u003c\/td\u003e\n\u003ctd\u003eIndicates battery status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Key\u003c\/td\u003e\n\u003ctd\u003ePower On\/Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Key\u003c\/td\u003e\n\u003ctd\u003eA DC zeroing function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csup\u003e[2]\u003c\/sup\u003e \u0026lt;1% range, unspecified\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hydromatics Limited","offers":[{"title":"Default Title","offer_id":53051384267118,"sku":null,"price":0.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/7812\/1070\/files\/Untitled_5x5in_4.png?v=1764856138","url":"https:\/\/www.hydromaticsea.com\/products\/fluke-283-fc-pv-solar-digital-multimeter-and-wireless-current-clamp","provider":"Hydromatics Limited","version":"1.0","type":"link"}