{"product_id":"fluke-2062-advanced-pro-wire-tracer-kit","title":"Fluke 2062 Advanced Pro Wire Tracer Kit","description":"\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eLocate energized and de-energized wires quickly and accurately in walls, ceilings, and floors\u003c\/li\u003e\n\u003cli\u003ePatented Smart Sensor™ locates and displays energized wires on color display\u003c\/li\u003e\n\u003cli\u003eFind breaks or opens and shorts, and identify breakers and fuses easily\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V safety rated\u003c\/li\u003e\n\u003cli\u003eIncludes the i400 AC Current Clamp accessory for inducing a tracing signal on the cable when there is no access to bare conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct overview: Fluke 2062 Advanced Pro Wire Tracer Kit\u003c\/h2\u003e\n\u003ch3\u003eBuilt to Keep You Safe\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 2062 Advanced Pro Wire Tracer accurately and safely troubleshoots energized and de-energized wires in residential, commercial, and industrial environments up to CAT IV 600 V. This CAT rating offers the highest protection available on any wire tracer. It’s designed to protect you from the most dangerous levels of transient overvoltage, spikes up to 8,000 V, that can occur in industrial and utility environments. This is especially important for scenarios you may encounter in environments like industrial plants, factories, and hospitals where critical equipment cannot be taken offline.\u003c\/p\u003e\n\u003ch3\u003eSmarter Tracing Saves Time\u003c\/h3\u003e\n\u003cp\u003eThe patented Smart Sensor™, available only on the Fluke 2062, makes wire tracing faster and easier. It locates and displays energized wires within walls, floors, and ceilings on a high-resolution 3.5-inch TFT LCD color display. Embedded help screens on the display makes it easy to use, whether you’re a novice or an expert. While the tip sensor provides an audible tone when locating wires, the Smart Sensor helps visualize and pinpoint the orientation of energized wires, eliminating guesswork.\u003c\/p\u003e\n\u003ch3\u003eWire Tracing Customized for Your Application\u003c\/h3\u003e\n\u003cp\u003eWhether troubleshooting electrical wiring and equipment in residential homes, commercial buildings, or high-voltage utility plants, the Fluke 2062 can find breaks or opens and shorts. Its different modes and functions give you the flexibility to troubleshoot a wide range of electrical wiring and circuitry problems you may encounter on the job.\u003c\/p\u003e\n\u003ch3\u003eFour Receiver Tracing Modes\u003c\/h3\u003e\n\u003cp\u003eThe 2062-R Receiver detects the signal in wires and cables using two methods: passive tracing without the transmitter for non-contact voltage detection and active tracing with the transmitter for all other modes. The receiver’s tip sensor can trace wires in corners, tight spaces, and junction boxes.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e“Smart Sensor” mode for energized wire detection and visualization on the large color LCD\u003c\/li\u003e\n\u003cli\u003e“Tip Sensor” mode for more precise detection of a wire\u003c\/li\u003e\n\u003cli\u003e“Breaker” mode for easy breaker and fuse identification based on the highest recorded signal detected from the transmitter\u003c\/li\u003e\n\u003cli\u003e“Non-Contact Voltage Detection” mode to trace energized wires without the use of the transmitter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThree Transmitter Power Modes\u003c\/h3\u003e\n\u003cp\u003eThe 2000-T Transmitter works on energized and de-energized circuits up to CAT IV 600 V and features high, low, and loop modes. These modes change the strength of the induced signal and can help provide more accurate results, depending on the circuit you’re tracing.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e“High” mode for normal energized and de-energized circuits\u003c\/li\u003e\n\u003cli\u003e“Low” mode for precision tracing with a low signal to reduce coupling to nearby wires and metal objects\u003c\/li\u003e\n\u003cli\u003e“Loop” mode for closed loop de-energized circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTwo Transmitter Output Frequencies\u003c\/h3\u003e\n\u003cp\u003eThe 2000-T automatically senses whether the system is energized or de-energized and selects a 6 kHz or 33 kHz output frequency.\u003c\/p\u003e\n\u003ch3\u003eEight Receiver Sensitivity Levels\u003c\/h3\u003e\n\u003cp\u003eMore sensitivity levels mean more flexibility and accuracy when tracing.\u003c\/p\u003e\n\u003ch3\u003eComplete Kit\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 2062 Advanced Pro Wire Tracer Kit conveniently comes with everything required to start tracing wires and circuits. The accessory kit includes test leads, test probes, blade and round outlet adapters, and alligator clips to connect the transmitter to electrical systems. Connecting the transmitter to a bare conductor with the included alligator clips and test leads will always provide the most accurate results. However, in situations where a direct connection to a bare conductor is not available, the included i400 Current Clamp can be used with the “Loop” mode to induce a boosted 6 kHz signal through the insulation. The kit also includes a magnetic hanger strap, batteries, and a hard carrying case.\u003c\/p\u003e\n\u003ch2\u003eSpecifications: Fluke 2062 Advanced Pro Wire Tracer Kit\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"1175\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\" width=\"249\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"404\"\u003e\u003cstrong\u003e2062R Receiver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"297\"\u003e\u003cstrong\u003e2000T Transmitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"225\"\u003e\u003cstrong\u003ei400 AC Current Clamp\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eMeasurement category\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V, CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e600 V AC\/DC\u003c\/td\u003e\n\u003ctd\u003e600 V AC\/DC\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\"\u003e\n\u003ctd height=\"41\"\u003eOperating frequency\u003c\/td\u003e\n\u003ctd width=\"404\"\u003eEnergized: 6.25 kHz\u003cbr\u003eDe-Energized: 32.768 kHz\u003c\/td\u003e\n\u003ctd width=\"297\"\u003eEnergized\/Loop: 6.25 kHz\u003cbr\u003eDe-Energized: 32.768 kHz\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eSignal indications\u003c\/td\u003e\n\u003ctd\u003eNumeric, bar graph display and audible beep\u003c\/td\u003e\n\u003ctd\u003eLEDs and audible beep\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"88\"\u003e\n\u003ctd height=\"88\"\u003eResponse time\u003c\/td\u003e\n\u003ctd width=\"404\"\u003eSmart Sensor: 500 ms\u003cbr\u003eTip Sensor (Energized\/De-Energized): 500 ms\u003cbr\u003eNCV: 500 ms\u003cbr\u003eBattery monitoring: 5 s\u003c\/td\u003e\n\u003ctd width=\"297\"\u003eLine voltage monitoring: 1 s\u003cbr\u003eBattery voltage monitoring: 5 s\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"207\"\u003e\n\u003ctd height=\"207\"\u003eCurrent output of signal (typical)\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd width=\"297\"\u003e\n\u003cspan\u003e\u003cstrong\u003eEnergized circuit:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHigh mode: 60 mA rms\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLow mode: 30 mA rms\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eDe-energized circuit:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHigh mode: 110 mA rms\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLow mode: 40 mA rms\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLoop mode with test leads: 160 mA rms\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLoop mode with i400 AC Current Clamp:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e385 mA rms\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"310\"\u003e\n\u003ctd height=\"310\"\u003eSignal voltage output (nominal)\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd width=\"297\"\u003e\n\u003cspan\u003e\u003cstrong\u003eEnergized circuit:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHigh mode: 14 W @ 230 V ac\/50 Hz,\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e3.33 kΩ @ 230 V ac\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLow mode: 4.6 W @ 230 V ac\/50 Hz,\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e11.5 kΩ @ 230 V ac\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eDe-energized circuit:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHigh mode: 31 V RMS, 140 Vp-p,\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.86 W @ 1 kΩ load\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLow mode: 27.5 V RMS, 120 Vp-p,\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.1 W @ 1 kΩ load\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLoop mode with test leads: 32 V RMS,\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e140 Vp-p, 0.87 W @ 1 kΩ load\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLoop mode with i400 AC Current Clamp:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e31 mV, 0.89 W @ 1 Ω load\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"248\"\u003e\n\u003ctd height=\"248\"\u003eRange detection (open air)\u003c\/td\u003e\n\u003ctd width=\"404\"\u003e\n\u003cspan\u003e\u003cstrong\u003eSmart Sensor Direction Indication Mode\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e≤15 cm (6 in), 230 V AC,\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ehigh mode, sensitivity level 2\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eTip Sensor: Energized\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eMax distance via air: up to 6.1 m (20 ft)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ePinpointing: approx. 5 cm (1.97 in)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eTip Sensor: De-Energized\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eMax distance via air: up to 4.5 m (14.7 ft)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ePinpointing: approx. 5 cm (1.97 in)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eNCV (40 Hz to 400 Hz)\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eMax. sensitivity: 90 V up to 2 m\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eMin. sensitivity: 600 V up to 1 cm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eCurrent range\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\"\u003e\n\u003ctd height=\"41\"\u003eBasic accuracy\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd width=\"225\"\u003e2 % + 0.06 A\u003cbr\u003e(45 Hz to 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"1175\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\" width=\"249\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"404\"\u003e \u003c\/td\u003e\n\u003ctd width=\"297\"\u003e \u003c\/td\u003e\n\u003ctd width=\"225\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eDisplay size\u003c\/td\u003e\n\u003ctd\u003eLCD 89 mm (3.5 in)\u003c\/td\u003e\n\u003ctd\u003eLEDs\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eDisplay dimensions (W x H)\u003c\/td\u003e\n\u003ctd width=\"404\"\u003e70 mm x 52 mm (2.76 in x 2.07 in )\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e480 px x 320 px\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eDisplay type\u003c\/td\u003e\n\u003ctd\u003eColor TFT LCD\u003c\/td\u003e\n\u003ctd\u003eLEDs\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\"\u003e\n\u003ctd height=\"41\"\u003eDisplay color\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003ctd width=\"297\"\u003eOperating mode LEDs: red\u003cbr\u003eBattery status LEDs: green, yellow, red\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"1175\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\" width=\"249\"\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"404\"\u003e \u003c\/td\u003e\n\u003ctd width=\"297\"\u003e \u003c\/td\u003e\n\u003ctd width=\"225\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C to 50 °C (-4 °F to 122 °F)\u003c\/td\u003e\n\u003ctd\u003e-20 °C to 50 °C (-4 °F to 122 °F)\u003c\/td\u003e\n\u003ctd\u003e-20 °C to 50 °C (-4 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"165\"\u003e\n\u003ctd height=\"165\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd width=\"404\"\u003e45%: -20 °C to \u0026lt;10 °C or 40 °C to 50 °C\u003cbr\u003e(-4 °F to \u0026lt;50 °F or 104 °F to 122 °F)\u003cbr\u003e95% (non-condensing): 10 °C to \u0026lt;30 °C\u003cbr\u003e(50 °F to 86 °F)\u003cbr\u003e75%: 30 °C to \u0026lt;40 °C (86 °F to \u0026lt;104 °F)\u003c\/td\u003e\n\u003ctd width=\"297\"\u003e45%: -20 °C to \u0026lt;10 °C or 40 °C to 50 °C\u003cbr\u003e(-4 °F to \u0026lt;50 °F or 104 °F to 122 °F)\u003cbr\u003e95% (non-condensing): 10 °C to \u0026lt;30 °C\u003cbr\u003e(50 °F to 86 °F)\u003cbr\u003e75%: 30 °C to \u0026lt;40 °C (86 °F to \u0026lt;104 °F)\u003c\/td\u003e\n\u003ctd width=\"225\"\u003e10 °C to \u0026lt;30 °C\u003cbr\u003e(95 %: 50 °F to \u0026lt;86 °F)\u003cbr\u003e30 °C to \u0026lt;40 °C\u003cbr\u003e(75 %: 86 °F to \u0026lt;104 °F)\u003cbr\u003e40 °C to \u0026lt;50 °C\u003cbr\u003e(45 %: 104 °F to \u0026lt;122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m (6561 ft)\u003c\/td\u003e\n\u003ctd\u003e2000 m (6561 ft)\u003c\/td\u003e\n\u003ctd\u003e2000 m (6561 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eTransient protection\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e8.00 kV (1.2\/50μS surge)\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003ePollution degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eIP rating\u003c\/td\u003e\n\u003ctd\u003eIP 40\u003c\/td\u003e\n\u003ctd\u003eIP 40\u003c\/td\u003e\n\u003ctd\u003eIP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eDrop test\u003c\/td\u003e\n\u003ctd\u003e1 m (3.28 ft)\u003c\/td\u003e\n\u003ctd\u003e1 m (3.28 ft)\u003c\/td\u003e\n\u003ctd\u003e1 m (3.28 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"1175\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\" width=\"249\"\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"404\"\u003e \u003c\/td\u003e\n\u003ctd width=\"297\"\u003e \u003c\/td\u003e\n\u003ctd width=\"225\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e4 x AA (alkaline)\u003c\/td\u003e\n\u003ctd\u003e8 x AA (alkaline)\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"83\"\u003e\n\u003ctd height=\"83\"\u003ePower consumption (typical)\u003c\/td\u003e\n\u003ctd\u003e110 mA\u003c\/td\u003e\n\u003ctd width=\"297\"\u003eHigh\/low mode: 70 mA\u003cbr\u003eLoop mode with Clamp: 90 mA\u003cbr\u003eConsumption without signal\u003cbr\u003etransmission: 10 mA\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\"\u003e\n\u003ctd height=\"41\"\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003eApprox. 20 h\u003c\/td\u003e\n\u003ctd width=\"297\"\u003eHigh\/low mode: approx. 25 h\u003cbr\u003eLoop mode: approx. 18 h\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eLow battery indication\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\"\u003e\n\u003ctd height=\"41\"\u003eFuse\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd width=\"297\"\u003e1.6 A, 700 V, fast-acting,\u003cbr\u003eØ 6 x 32 mm, 50 kA interrupt\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eMaximum conductor size\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e32 mm (1.26 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\"\u003e\n\u003ctd height=\"41\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd width=\"404\"\u003eApprox. 277 x 112 x 65 mm\u003cbr\u003e(10.92 x 4.43 x 2.55 in)\u003c\/td\u003e\n\u003ctd width=\"297\"\u003eApprox. 183 x 93 x 50 mm\u003cbr\u003e(7.2 x 3.66 x 1.97 in)\u003c\/td\u003e\n\u003ctd width=\"225\"\u003eApprox. 150 x 70 x 30 mm\u003cbr\u003e(5.9 x 2.75 x 1.18 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.544 kg (1.20 lb)\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.57 kg (1.25 lb)\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.114 kg (0.25 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"653\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\" width=\"249\"\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"404\"\u003e\u003cstrong\u003e2000ACC Test Lead Accessory Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"124\"\u003e\n\u003ctd height=\"124\"\u003eIncludes\u003c\/td\u003e\n\u003ctd width=\"404\"\u003e2x 1 m test leads (red, black),\u003cbr\u003e1x 7 m test lead (green),\u003cbr\u003e2x test probes (black),\u003cbr\u003e2x alligator clips (red, black),\u003cbr\u003e2x outlet blade adapters (red, black),\u003cbr\u003e2x outlet round adapters (red, black)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"62\"\u003e\n\u003ctd height=\"62\"\u003eMeasurement category\u003c\/td\u003e\n\u003ctd width=\"404\"\u003eCAT IV 600 V (test leads), CAT II 1000 V (test probes), CAT IV 600 V (alligator clips),\u003cbr\u003eCAT II 300 V (outlet adapters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"83\"\u003e\n\u003ctd height=\"83\"\u003eOperating voltage and current\u003c\/td\u003e\n\u003ctd width=\"404\"\u003e600 V, 10 A max. (red\/black leads), 600 V, 10 A max. (green lead), 1000 V, 8 A max. (black probe)\u003cbr\u003e600 V, 10 A max. (alligator clips), 300 V, 10 A max. (outlet adapters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 50 °C (32 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"62\"\u003e\n\u003ctd height=\"62\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd width=\"404\"\u003e10 °C to \u0026lt;30 °C (95 %: 50 °F to \u0026lt;86 °F), 30 °C to \u0026lt;40 °C (75 %: 86 °F to \u0026lt;104 °F),\u003cbr\u003e40 °C to \u0026lt;50 °C (45 %: 104 °F to \u0026lt;122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eStorage temperature and humidity\u003c\/td\u003e\n\u003ctd\u003e0 °C to 60 °C (32 °F to 140 °F), \u0026lt;95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m (6561 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003ePollution degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eWater and dust resistance\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eDrop proof\u003c\/td\u003e\n\u003ctd\u003e1 m (3.28 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"103\"\u003e\n\u003ctd height=\"103\"\u003eDimensions\u003c\/td\u003e\n\u003ctd width=\"404\"\u003eRed\/black leads: 1 m (3.28 ft), Green lead: 7 m (22.97 ft), Alligator clips: approx. 95 x 45 x 24 mm (3.74 x 1.77 x 0.94 in),\u003cbr\u003eOutlet adapters: 72 x 18 x 18 mm (2.83 x 0.71 x 0.71 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.4 kg (0.88 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hydromatics Limited","offers":[{"title":"Default Title","offer_id":53289300787566,"sku":null,"price":0.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/7812\/1070\/files\/fluke2062.png?v=1770624520","url":"https:\/\/www.hydromaticsea.com\/products\/fluke-2062-advanced-pro-wire-tracer-kit","provider":"Hydromatics Limited","version":"1.0","type":"link"}