{"product_id":"fluke-1777-three-phase-power-quality-analyzer-with-current-probes-and-wifi-ble-adaptor-8-kv","title":"Fluke 1777 Three-Phase Power Quality Analyzer with current probes and WiFi\/BLE adaptor, 8 kV","description":"\u003ch4\u003eFluke 1777 Offers\u003c\/h4\u003e\n\u003cp\u003eMake data capture as reliable and easy as possible with the power quality analyzer that features instrument powering from the measurement circuit, automatic connection check, and correction.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe Fluke 1777 Power Quality Analyzer replaces the discontinued 1750-TF\/ET, 1750-TF\/NT, 1750\/ET, 1750\/NT Three-Phase Power Quality Recorder\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatically measure power and power quality parameters\u003c\/li\u003e\n\u003cli\u003ePower system connection and instrument setup autocorrection\u003c\/li\u003e\n\u003cli\u003eInstrument automatically detects error in voltage and current wiring, providing correction without rewiring\u003c\/li\u003e\n\u003cli\u003eHigh resolution touchscreen\u003c\/li\u003e\n\u003cli\u003eCapacitive touchscreen allows use with PPE (double gloved hands), providing clear results in seconds\u003c\/li\u003e\n\u003cli\u003ePower quality health summary: automatically evaluate power quality inputs against the EN 50160 electrical standard, providing detailed troubleshooting of power quality problem areas\u003c\/li\u003e\n\u003cli\u003eHarmonics: multiple methods of harmonic analysis provide users with the data they increasingly need with basic fundamental to 50 integer harmonics, 2 to 9 kHz for IEC61000-4-30 Annex A compliance and harmonics to 30 kHz harmonics to discover the effects of inverters on the network\u003c\/li\u003e\n\u003cli\u003eCritical power quality data is captured as soon as you begin a session, without extensive setup or selections\u003c\/li\u003e\n\u003cli\u003eIntuitive user interface makes it easy to navigate between measurement parameters like V\/A\/Hz, power, dips and swells, harmonics, or PQ health at the push of a button\u003c\/li\u003e\n\u003cli\u003eCapture damaging high-speed transients so you can mitigate their effects before equipment fails\u003c\/li\u003e\n\u003cli\u003eAnalysis and reporting comes standard with Fluke Energy Analyze Plus software giving you the ability to create customized reports, or leverage built-in one-click reporting to industry standards like EN 50160, IEEE 519 and GOST 33073\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBasic power studies\u003c\/li\u003e\n\u003cli\u003eBasic power quality studies\u003c\/li\u003e\n\u003cli\u003eAdvanced power studies\u003c\/li\u003e\n\u003cli\u003eAdvanced power quality studies\u003c\/li\u003e\n\u003cli\u003eEnergy surveys\u003c\/li\u003e\n\u003cli\u003eLoad studies\u003c\/li\u003e\n\u003cli\u003eCapture events\u003c\/li\u003e\n\u003cli\u003eView event waveform data on screen\u003c\/li\u003e\n\u003cli\u003eMains signal monitoring\u003c\/li\u003e\n\u003cli\u003eHarmonic surveys\u003c\/li\u003e\n\u003cli\u003eNuisance circuit breaker tripping\u003c\/li\u003e\n\u003cli\u003ePower utility power quality surveys\u003c\/li\u003e\n\u003cli\u003eDiscovery of equipment failures caused by transients\u003c\/li\u003e\n\u003cli\u003eCapture the highest speed, high magnitude voltage that can be most damaging\u003c\/li\u003e\n\u003cli\u003eData center monitoring and maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span4 text-center\"\u003e\u003cimg src=\"https:\/\/www.fluke-direct.com\/images\/specialty-pages\/fluke-1770-bonus-content\/fluke-1770-series-application1.jpg\" class=\"\" alt=\"Fluke 1700 Series application shot\" data-pagespeed-url-hash=\"3611332246\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"span4 text-center\"\u003e\u003cimg src=\"https:\/\/www.fluke-direct.com\/images\/specialty-pages\/fluke-1770-bonus-content\/fluke-1770-series-application2.jpg\" class=\"\" alt=\"Fluke 1700 Series application shot\" data-pagespeed-url-hash=\"3905832167\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"span4 text-center\"\u003e\u003cimg src=\"https:\/\/www.fluke-direct.com\/images\/specialty-pages\/fluke-1770-bonus-content\/fluke-1770-series-application3.jpg\" class=\"\" alt=\"Fluke 1700 Series application shot\" data-pagespeed-url-hash=\"4200332088\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic measurements. More flexibility. Better power quality troubleshooting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe three-phase power quality analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord. With the 1770 Series you’ll never miss a critical power quality event—from fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic measurement capture\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhether you’re performing a quick system check or a detailed power quality study, consistent data is key. The power quality analyzer offers a unique automatic measurement capture system that helps ensure you’re collecting the right data every time, while still giving you the flexibility to select and adjust specific parameters as needed. More than 500 power quality parameters are captured by default and the guided setup makes it easy to select the right parameters for the system you’re working on. Logged data is instantly viewable, downloadable, and shareable with Fluke Energy Analyze Plus software so you never need to wait to finish a session before reviewing results or analyzing data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUltimate measurement confidence\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe three-phase power quality analyzers are 2-in-1 devices that combine the troubleshooting functionality of a power quality meter with the robust analysis and logging capabilities of a standalone power quality analyzer—in a single, easy-to-use, handheld device.\u003c\/p\u003e\n\u003cp\u003eThe ‘PQ Meter’ function gives you immediate access to live onscreen data in the field so you can quickly identify potential problems while troubleshooting. The detailed ‘PQ Logging and Analysis’ function eliminates the complexity of performing power quality studies by guiding you through the setup process ensuring you’re capturing the right data every time. Couple these measurement modes with a unique measurement connection autocorrect function and you can be confident that you never need to worry about going back for a second measurement—even if you were unsure about what to look for when you started.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"row-fluid well fluke-bonus-well-box\"\u003e\n\u003cdiv class=\"span4\"\u003e\n\u003cimg src=\"https:\/\/www.fluke-direct.com\/images\/specialty-pages\/fluke-1770-bonus-content\/fluke-1700-series-transient-capture.png\" class=\"\" alt=\"Fluke 1700 Series transient capture\" data-pagespeed-url-hash=\"930697609\"\u003e\u003csmall\u003eView real-time voltage transitory events while logging for faster troubleshooting\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"span8\"\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-speed voltage transient capture\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTransients negatively impact otherwise healthy systems every day and their potential to damage your equipment can’t be underestimated. Whether your system is experiencing impulsive or oscillatory transients, the results can be devastating and cause problems ranging from insulation failures to total equipment failures. The\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke-direct.com\/product\/fluke-1775-power-quality-analyzer\" class=\"\" target=\"_blank\"\u003e1775\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke-direct.com\/product\/fluke-1777-power-quality-analyzer\" class=\"\" target=\"_blank\"\u003e1777\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincorporate advanced transient capture technology to help you clearly identify high-speed voltage transients, so you have the data you need to stop them in their tracks. The\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke-direct.com\/product\/fluke-1775-power-quality-analyzer\" class=\"\" target=\"_blank\"\u003e1775 Power Quality Analyzer\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003ehas 1MHz sampling capability to capture fast transients, while the\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke-direct.com\/product\/fluke-1777-power-quality-analyzer\" class=\"\" target=\"_blank\"\u003e1777 Power Quality Analyzer\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003ehas 20 MHz sampling capability to capture the fastest transients in high detail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row-fluid well fluke-bonus-well-box\"\u003e\n\u003cdiv class=\"span4\"\u003e\n\u003cimg src=\"https:\/\/www.fluke-direct.com\/images\/specialty-pages\/fluke-1770-bonus-content\/fluke-1700-series-industrial-systems-capture.png\" class=\"\" alt=\"Fluke 1700 Series industrial systems capture\" data-pagespeed-url-hash=\"4032361433\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003csmall\u003eA full range of harmonics are available from the first 50 integer harmonics and from 2 kHz to 30 kHz\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"span8\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrom traditional industrial systems to renewable energy systems to electric vehicles, we’ve got you covered\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe three-phase power quality analyzer was designed to be safe and easy to use in any measurement environment. The three-phase power quality analyzer allows you to capture a full range of power quality variables as well as high-speed waveforms, high-speed transients, and higher frequency harmonics, all of which are instantly viewable on the large, high-resolution screen. With a best-in-class CAT IV 600 V \/ CAT III 1000 V overvoltage rating, these analyzers can be used at the service entrance or downstream, measuring AC and DC inputs, and harmonics measuring up to 30 kHz. With the 1770 Series you can be confident that you’ll capture the data you need to make better maintenance decisions no matter the task.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row-fluid well fluke-bonus-well-box\"\u003e\n\u003cdiv class=\"span4\"\u003e\n\u003cimg src=\"https:\/\/www.fluke-direct.com\/images\/specialty-pages\/fluke-1770-bonus-content\/fluke-1770-touchscreen-image.jpg\" class=\"\" alt=\"Fluke 1700 Series large color touchscreen\" data-pagespeed-url-hash=\"3298018680\"\u003e\u003csmall\u003eEasily navigate using the large color touchscreen\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"span8\"\u003e\n\u003cp\u003e\u003cstrong\u003eWork where, when, and how you want\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo two days in the field are the same. You need a power quality analyzer that can go where you go and do what you need it to when you get there. With a full range of accessories and built-in features the 1770 Series makes it easier to get your job done. The slim ergonomic design and integrated hand strap make it easy to hold and the included hanging kit makes it easy to secure your analyzer inside a cabinet. The integrated internal power supply allows the unit to be powered directly from the measured circuit, while a 90-minute battery helps ensure you can still access and review data even when you aren’t connected to a live system.\u003c\/p\u003e\n\u003cp\u003eQuickly and easily transfer data to your PC using the USB C, USB A, Ethernet, WiFi, cellular network support options, depending on your requirements. With an internal GPS module and an optional double insulated external antenna, you can time sync your data for more accurate troubleshooting and analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row-fluid well fluke-bonus-well-box\"\u003e\n\u003cdiv class=\"span4\"\u003e\n\u003cimg src=\"https:\/\/www.fluke-direct.com\/images\/specialty-pages\/fluke-1770-bonus-content\/fluke-1700-series-harmonics-limits-capture.png\" class=\"\" alt=\"Fluke 1700 Series harmonics limits capture\" data-pagespeed-url-hash=\"137072792\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003csmall\u003eIndividual harmonics can be easily selected to view trend data as loads change\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"span8\"\u003e\n\u003cp\u003e\u003cstrong\u003eCalculate current harmonics limits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen downloading data from the 1770 Series Power Quality Analyzers the included Energy Analyze Plus software package can compare measured voltage and current harmonic statistical data to different standards, like EN 50160 or IEEE 519, to determine if they exceed compliance limits. This powerful predictive maintenance feature enables current harmonics to be observed before distortion appears in the voltage allowing you to prevent unexpected failures or non-compliance situations and increase system uptime. With the proliferation of inverter-based loads and power generation, keeping current harmonics in check is becoming increasingly critical to ensure reliable power quality and avoid system downtime.\u003c\/p\u003e\n\u003ch4\u003eFluke 1777 Specifications\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e4 inputs, 3 phases and neutral referenced to PE (5 connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Category\u003c\/td\u003e\n\u003ctd\u003e1000 V CAT III\/600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V rms\/1000 V DC (1700 Vpk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage Range\u003c\/td\u003e\n\u003ctd\u003eWye and single phase: variable (50 to 1000 V)\u003cbr\u003eDelta: variable (100 to 1000 V)\u003cbr\u003eIEC 61000-4-30 Class A compliance for the nominal voltages (V\u003csub\u003edin\u003c\/sub\u003e) 100 to 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003eDC to 30 kHz for PQ measurements, excluding transients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e24-bit synchronous sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Frequency\u003c\/td\u003e\n\u003ctd\u003e80 kS\/second at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScaling\u003c\/td\u003e\n\u003ctd\u003e1:1 variable for use of potential transformers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage Transients\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e±8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e1 MS\/second\u003cbr\u003e20 MS\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003eDC to 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger\u003c\/td\u003e\n\u003ctd\u003eAdjustable trigger level\u003cbr\u003eTriggers on high-frequency components \u0026gt;1.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e14-bit synchronous sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCurrent Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Inputs\u003c\/td\u003e\n\u003ctd\u003e4 inputs 3 phases and neutral, range selected automatically to attached sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003eDC to 30 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e24-bit synchronous sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Frequency\u003c\/td\u003e\n\u003ctd\u003e80 kS\/second at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScaling\u003c\/td\u003e\n\u003ctd\u003e1:1 variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003eClamp: 50 mV\/500 mV rms; CF 2.8\u003cbr\u003eRogowski coil: 15 mV\/150 mV rms at 50 Hz, 18 mV\/180 mV rms at 60 Hz; CF 4\u003cbr\u003eAll at nominal probe range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e11 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eData Acquisition Voltage and Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Mains Frequency\u003c\/td\u003e\n\u003ctd\u003eDC, 50\/60 Hz ±15% (42.5 to 57.5 Hz, 51 to 69 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopologies\u003c\/td\u003e\n\u003ctd\u003e1-φ, 1-φ IT, split phase, 3-φ delta, 3-φ wye IT, 3-φ aron\/blondel (2 element delta), 3-φ delta open leg, 3-φ high leg delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003e32 GB microSD card (installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Size\u003c\/td\u003e\n\u003ctd\u003eTypical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events\u003cbr\u003eThe number of possible logging sessions and logging period depends on user requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-time Accuracy\u003c\/td\u003e\n\u003ctd\u003eInternal: 3 ppm (0.26 s per day, 8 s per month)\u003cbr\u003eNTP (internet time): depending on internet latency, typical \u0026lt;0.1 s absolute to UTC\u0026lt;br\u0026gt; GPS: \u0026lt;1 ms absolute to UTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11.0 x 7.5 x 2.4\" (28 x 19 x 6.2 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.6 lbs (2.1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hydromatics Limited","offers":[{"title":"Default Title","offer_id":53278743200110,"sku":null,"price":0.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/7812\/1070\/files\/Untitleddesign-2026-02-05T152112.593.png?v=1770294130","url":"https:\/\/www.hydromaticsea.com\/products\/fluke-1777-three-phase-power-quality-analyzer-with-current-probes-and-wifi-ble-adaptor-8-kv","provider":"Hydromatics Limited","version":"1.0","type":"link"}