{"product_id":"fluke-1664-fc-installation-multifunction-testers","title":"Fluke 1664 FC Installation Multifunction Testers","description":"\u003ch2 class=\"features-title\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cp\u003eMultifunction tester that tests to all local regulations\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes \"Insulation Pre-test\" that detects when appliances are connected to the system and stops the test\u003c\/li\u003e\n\u003cli\u003eRuns seven installation tests automatically in one sequence with a single connection through Auto Test\u003c\/li\u003e\n\u003cli\u003eAllows you to share test results in real time over your smartphone via Fluke Connect Measurements\u003c\/li\u003e\n\u003cli\u003e6 mA RDC-DD testing for EV charging stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct overview: Fluke 1664 FC Installation Multifunction Testers\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003ch3\u003eThe Fluke 1664 FC Multifunction Installation Tester helps expedite installations\u003c\/h3\u003e\n\u003cp\u003eThe 1664 FC puts a lot of testing power in your hands to quickly and efficiently test to all local regulations, protect appliances, and share test results in real time over your smartphone.\u003c\/p\u003e\n\u003ch3\u003eTest EV charging station RCD type A-EV or RDC-DD DC protection devices\u003c\/h3\u003e\n\u003cp\u003ePerform tests on EV charging station DC protection devices using the RCD type B (smooth DC currents) VAR mode, which generates the test currents for RCD type A-EV or RDC-DD acc. to IEC 62955 (6\/60\/200 mA and ramp \u0026lt;2 to 6 mA ramp). This allows the quick an easy testing of additional 6 mA DC monitors on charging points and can be used in conjunction with the Fluke FEV100 or FEV300.\u003c\/p\u003e\n\u003ch3\u003eProtect appliances from accidental damage\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1664 FC is the only tester with \"\"Insulation PreTest\"\" that stops the insulation test and provides a visual warning if it detects that an appliance is connected to the system under test. This helps you avoid potentially serious and costly mistakes that can cause damage to your customers’ peripheral equipment.\u003c\/p\u003e\n\u003ch3\u003eAuto Test reduces test time\u003c\/h3\u003e\n\u003cp\u003eAuto Test performs up to seven installation tests in one sequence, ensuring compliance with local installation regulations. This reduces the number of manual connections, thus decreasing the possibility of errors and reducing test time.\u003c\/p\u003e\n\u003ch3\u003eSave time and enhance collaboration\u003c\/h3\u003e\n\u003cp\u003eBecause the 1664 FC is Fluke Connect®-enabled, you can send test results to your smartphone, save them to the cloud, and share measurements in real time with team members through a ShareLive video call. It's the fastest way to let your team see what you see, and to help you get approvals without leaving the field. Fluke Cloud™ storage allows you to retrieve stored results whether you are in the office or in the field to make decisions in real time. You get world-class data protection and can import the data, manage files transferred from instruments, or manually enter data as needed into TruTest™ Software to process and generate certificates quickly and easily. Designed to eliminate the hassle associated with traditional electrical system data management and reporting, TruTest™ Software is an ideal solution for producing easy-to-understand reports for clients.\u003c\/p\u003e\n\u003ch3\u003eOther helpful features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact, lightweight (less than 1.3 kg) with padded neck-strap to free your hands\u003c\/li\u003e\n\u003cli\u003eRotary dial knob clearly indicates which function is selected, all in one spot with no complex multi-level menus.\u003c\/li\u003e\n\u003cli\u003eOffers additional high current loop mode for faster measurements than loop tests with non-trip mode for RCDs\u003c\/li\u003e\n\u003cli\u003eIncludes Z-max memory for loop tests to support easy evaluation of the highest loop test value\u003c\/li\u003e\n\u003cli\u003eProvides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation\u003c\/li\u003e\n\u003cli\u003ePerforms fast voltage measurement between L-N, L-PE, and N-PE using the mains cord. No need to change measurement connections\u003c\/li\u003e\n\u003cli\u003eMeasures RCD trip current and trip time in parallel (RCD type AC and A)\u003c\/li\u003e\n\u003cli\u003eMeasures PEFC or PSC and loop impedance in parallel and displays them together on the dual display\u003c\/li\u003e\n\u003cli\u003eOffers ring testing so you can select the required input sockets with soft keys and not have to exchange test leads\u003c\/li\u003e\n\u003cli\u003eUses continuity test currents to measure motor windings\u003c\/li\u003e\n\u003cli\u003eDetects raised earth voltages \u0026gt; 50 V with Earth Volt Touchpad, indicating potential dangerous situations\u003c\/li\u003e\n\u003cli\u003eFeatures large display with backlight, clear symbols, and exceptionally wide viewing angle for easy and safe readings\u003c\/li\u003e\n\u003cli\u003eOffers extended three-layer memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1664 FC Installation Multifunction Testers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003cp\u003eSpecifications: Fluke 1663 and 1664 FC Installation Multifunction Testers\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"637\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd colspan=\"3\" height=\"21\" width=\"637\"\u003e\u003cstrong\u003eAC voltage measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eAccuracy 45 Hz – 66 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.8% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e360 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e660 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd colspan=\"3\" height=\"21\"\u003e\u003cstrong\u003eContinuity testing (RLO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eRange (autoranging)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20 Ω \/ 200 Ω \/ 2000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eOpen Circuit Voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd colspan=\"3\" height=\"21\"\u003e\u003cstrong\u003eInsulation resistance measurement (RISO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eTest voltages\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50-100-250-500-1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\"\u003e\n\u003ctd height=\"41\" width=\"220\"\u003eAccuracy of test voltage (at rated test current)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+10%, -0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"105\"\u003e\n\u003ctd height=\"105\"\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e50 V\u003cbr\u003e100 V\u003cbr\u003e250 V\u003cbr\u003e500 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"105\"\u003e\n\u003ctd height=\"105\"\u003eInsulation resistance range\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e20 MΩ \/ 50 MΩ\u003cbr\u003e20 MΩ \/ 100 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ \/ 500 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ \/ 1000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"105\"\u003e\n\u003ctd height=\"105\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"105\"\u003e\n\u003ctd height=\"105\"\u003eTest current\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e1 mA @ 50 kΩ\u003cbr\u003e1 mA @ 100 kΩ\u003cbr\u003e1 mA @ 250 kΩ\u003cbr\u003e1 mA @ 500 kΩ\u003cbr\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd colspan=\"3\" height=\"21\"\u003e\u003cstrong\u003eLoop and line impedance (ZI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e10 Ω (Hi current mΩ mode)\/20 Ω\/200 Ω\/2000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e0.001 Ω\/ 0.01 Ω\/ 0.1 Ω\/1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd colspan=\"2\" height=\"21\"\u003e\u003cstrong\u003eProspective earth fault current, PSC test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e1000 A \/ 10 kA (50 kA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e1 A \/ 0.1 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"100\"\u003e\n\u003ctd height=\"100\"\u003eComputation\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003eProspective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd colspan=\"3\" height=\"21\"\u003e\u003cstrong\u003eRCD testing, RCD types tested\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"42\"\u003e\n\u003ctd height=\"42\"\u003eRCD Type\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003eAC¹\u003cbr\u003eG²,S³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eModel 1663\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003eA4, AC¹, G²,S³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eModel 1664 FC\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003eA, AC, B5, S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"112\"\u003e\n\u003ctd height=\"112\"\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e¹Responds to AC\u003cbr\u003e²General, no delay\u003cbr\u003e³Time delay\u003cbr\u003e⁴Responds to pulsed signal\u003cbr\u003e⁵Responds to smooth DC signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd colspan=\"3\" height=\"21\"\u003e\u003cstrong\u003eTripping speed test (ΔT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"43\"\u003e\n\u003ctd height=\"43\"\u003eCurrent settings¹\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e10-30-100-300-500-1000 mA – VAR\u003cbr\u003e10-30-100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"75\"\u003e\n\u003ctd height=\"75\"\u003eMultiplier\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003ex ½, x 1\u003cbr\u003ex 5\u003cbr\u003eVAR Mode Type B - 6, 60, 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\"\u003e\n\u003ctd rowspan=\"3\" height=\"144\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd width=\"255\"\u003eRCD Type G\u003c\/td\u003e\n\u003ctd width=\"162\"\u003e310 ms\u003cbr\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\"\u003e\n\u003ctd height=\"41\" width=\"255\"\u003eRCD Type S\u003c\/td\u003e\n\u003ctd width=\"162\"\u003e510 ms\u003cbr\u003e160 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"62\"\u003e\n\u003ctd height=\"62\"\u003eEV \/ RDC-DD\u003c\/td\u003e\n\u003ctd width=\"162\"\u003e6 mA - 10s\u003cbr\u003e60 mA - 0.3s\u003cbr\u003e200 mA - 0.1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"123\"\u003e\n\u003ctd height=\"123\"\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e¹1000 mA type AC only\u003cbr\u003e700 mA maximum type A in VAR mode\u003cbr\u003eThe VAR Mode at RCD type B (smooth DC currents) generates the test currents acc. to IEC 62955 for RCD type A-EV or RDC-DD (6\/60\/200 mA and ramp \u0026lt;2 to 6 mA).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd colspan=\"3\" height=\"21\"\u003e\u003cstrong\u003eRCD\/FI-Tripping Current Measurement\/Ramp Test (IΔN)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"45\"\u003e\n\u003ctd height=\"45\"\u003eCurrent range\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e30% to 110% of RCD rated current¹\u003cbr\u003e\u0026lt;2 mA to 6 mA smooth DC³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"42\"\u003e\n\u003ctd height=\"42\"\u003eStep size\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e10% of IΔN²\u003cbr\u003eLinear rising within 30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd rowspan=\"2\" height=\"42\"\u003eDwell time\u003c\/td\u003e\n\u003ctd width=\"255\"\u003eRCD Type G\u003c\/td\u003e\n\u003ctd width=\"162\"\u003e300 ms\/step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\" width=\"255\"\u003eRCD Type S\u003c\/td\u003e\n\u003ctd width=\"162\"\u003e500 ms\/step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"95\"\u003e\n\u003ctd height=\"95\" width=\"220\"\u003eSpecified trip current ranges (EN 61008-1)\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e50% to 100% for Type AC\u003cbr\u003e35% to 140% for Type A (\u0026gt;10 mA)\u003cbr\u003e35% to 200% for Type A (≤10 mA)\u003cbr\u003e50% to 200% for Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"106\"\u003e\n\u003ctd height=\"106\"\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"417\"\u003e¹30% to 150% for Type A IΔN \u0026gt; 10 mA\u003cbr\u003e30% to 210% for Type A IΔN = 10 mA\u003cbr\u003e20% to 210% for Type B\u003cbr\u003e²5% for Type B\u003cbr\u003e³For RCD type A-EV\/RDC-DD acc. to IEC 62955 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd colspan=\"3\" height=\"21\"\u003e\u003cstrong\u003eEarth Resistance Test (RE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e200 Ω \/ 2000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 Ω \/ 1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eFrequency\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e25 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd colspan=\"3\" height=\"21\" width=\"637\"\u003e\u003cstrong\u003ePhase Sequence Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"34\"\u003e\n\u003ctd height=\"34\"\u003eIcon\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cimg src=\"https:\/\/media.fluke.com\/647e0b42-affa-480c-a0d4-b108002ccdd2_original__size.jpg\" alt=\"icon phase sequence indicator\" width=\"28\" height=\"25\"\u003e\n\u003cp\u003e   Phase Sequence indicator is active.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd colspan=\"3\" height=\"21\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 x 25 x 12.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eWeight (incl. batteries)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.3 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eBattery size, quantity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eType AA, 6 ea.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eSealing\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with EN\/IEC 61010-1 and EN\/IEC 61010-2-034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003eOvervoltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCAT III \/ 500V; CAT IV 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\"\u003ePerformance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN61557-1 to EN61557-7 and EN61557-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hydromatics Limited","offers":[{"title":"Default Title","offer_id":53066674733422,"sku":null,"price":0.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/7812\/1070\/files\/Untitled_5x5in_42.png?v=1765445359","url":"https:\/\/www.hydromaticsea.com\/products\/fluke-1664-fc-installation-multifunction-testers","provider":"Hydromatics Limited","version":"1.0","type":"link"}