{"product_id":"fluke-15b-digital-multimeter","title":"Fluke 15B+ Digital Multimeter","description":"\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003e600 V Cat III safety rating\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage measurement up to 1000V\u003c\/li\u003e\n\u003cli\u003eAC\/DC current measurement up to 10A\u003c\/li\u003e\n\u003cli\u003eMeasures voltage, resistance, continuity, capacitance\u003c\/li\u003e\n\u003cli\u003eDiode test, data hold\u003c\/li\u003e\n\u003cli\u003eLarge easy-to-read display with bright white backlight\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct overview: Fluke 15B+ Digital Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003cp\u003e\u003cstrong\u003eFluke quality is always within your reach\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnlock professional-grade precision, durability, and safety with the Fluke 15B+ Digital Multimeter. The Fluke 15B+ packs all the core functionality you need in a digital multimeter into a portable, rugged form tool that’s easy-to-use with one hand, even with gloves on. From AC\/DC voltage and current measurements up to 1000V and 10A, to comprehensive capabilities including resistance, capacitance, and frequency checks, the 15B+ is your go-to for troubleshooting a wide array of electrical issues.\u003cbr\u003e\u003cbr\u003eThe CAT III 600V safety rating provides peace of mind for everything from routine checks on electrical equipment and appliances, to checking voltage levels at power outlets or switches, to diagnosing issues with circuits. Ideal for both DIY enthusiasts and early career electricians looking to streamline their toolkit, the Fluke 15B+ is a reliable and versatile addition to your toolkit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"overview-right\"\u003e\n\u003cdiv id=\"fluke-product-display-box-contents\"\u003e\n\u003ch3\u003eWhat's in the box:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 15B+ Digital Multimeter\u003c\/li\u003e\n\u003cli\u003eFluke TL75 Test Leads\u003c\/li\u003e\n\u003cli\u003e2 AA Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 15B+ Digital Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003ch2\u003eAccuracy Specifications\u003c\/h2\u003e\n\u003cp\u003eAccuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC volts\u003cbr\u003e(40 Hz to 500Hz)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e4.000 V\u003cbr\u003e40.00 V\u003cbr\u003e400.0 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003cbr\u003e0.01 V\u003cbr\u003e0.1 V\u003cbr\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC volts\u003c\/td\u003e\n\u003ctd\u003e4.000 V\u003cbr\u003e40.00 V\u003cbr\u003e400.0 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003cbr\u003e0.01 V\u003cbr\u003e0.1 V\u003cbr\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e0.5% + 3\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC millivolts\u003c\/td\u003e\n\u003ctd\u003e400.0 mV\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e3.0% + 3\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC millivolts\u003c\/td\u003e\n\u003ctd\u003e400.0 mV\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e1.0% + 10\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode test\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.000 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd\u003e10%\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003cbr\u003e(Ohms)\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω\u003cbr\u003e4.000 kΩ\u003cbr\u003e40.00 kΩ\u003cbr\u003e400.0 kΩ\u003cbr\u003e4.000 MΩ\u003cbr\u003e40.00 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003cbr\u003e0.001 kΩ\u003cbr\u003e0.01 kΩ\u003cbr\u003e0.1 kΩ\u003cbr\u003e0.001 MΩ\u003cbr\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.5% + 3\u003cbr\u003e0.5% + 2\u003cbr\u003e0.5% + 2\u003cbr\u003e0.5% + 2\u003cbr\u003e0.5% + 2\u003cbr\u003e1.5% + 3\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e40.00 nF\u003cbr\u003e400.0 nF\u003cbr\u003e4.000 μF\u003cbr\u003e40.00 μF\u003cbr\u003e400.0 μF\u003cbr\u003e1000 μF\u003c\/td\u003e\n\u003ctd\u003e0.01 nF\u003cbr\u003e0.1 nF\u003cbr\u003e0.001 μF\u003cbr\u003e0.01 μF\u003cbr\u003e0.1 μF\u003cbr\u003e1 μF\u003c\/td\u003e\n\u003ctd\u003e2% + 5\u003cbr\u003e2% + 5\u003cbr\u003e5% + 5\u003cbr\u003e5% + 5\u003cbr\u003e5% + 5\u003cbr\u003e5% + 5\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current μA\u003cbr\u003e(40 Hz to 400 Hz)\u003c\/td\u003e\n\u003ctd\u003e400.0 μA\u003cbr\u003e4000 μA\u003c\/td\u003e\n\u003ctd\u003e0.1 μA\u003cbr\u003e1 μA\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current mA\u003cbr\u003e(40 Hz to 400 Hz)\u003c\/td\u003e\n\u003ctd\u003e40.00 mA\u003cbr\u003e400.0 mA\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003cbr\u003e0.1 mA\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current A\u003cbr\u003e(40 Hz to 400 Hz)\u003c\/td\u003e\n\u003ctd\u003e4.000 A\u003cbr\u003e10.00 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003cbr\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC current μA\u003c\/td\u003e\n\u003ctd\u003e400.0 μA\u003cbr\u003e4000 μA\u003c\/td\u003e\n\u003ctd\u003e0.1 μA\u003cbr\u003e1 μA\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC current mA\u003c\/td\u003e\n\u003ctd\u003e40.00 mA\u003cbr\u003e400.0 mA\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003cbr\u003e0.1 mA\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC current A\u003c\/td\u003e\n\u003ctd\u003e4.000 A\u003cbr\u003e10.00 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003cbr\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eYes\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003csup\u003e1\u003c\/sup\u003eAC volts are specified from 1% to 100% of range. Inputs below 1% of range are not specified.\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003eTypically, open circuit test voltage is 2.0 V and short circuit current is \u0026lt;0.6 mA.\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003eSpecifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd\u003eInput impedance (Nominal)\u003c\/td\u003e\n\u003ctd\u003eCommon mode rejection ratio\u003c\/td\u003e\n\u003ctd\u003eNormal mode rejection ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC volts\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10 MΩ \u0026lt;100 pF\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;60 dB at dc,\u003cbr\u003e50 Hz or 60 Hz\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC millivolts\u003c\/td\u003e\n\u003ctd\u003e400 mV\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;1MΩ, \u0026lt;100 pF\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;80 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC volts\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10 MΩ \u0026lt;100 pF\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100 dB at dc,\u003cbr\u003e50 Hz or 60 Hz\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC millivolts\u003c\/td\u003e\n\u003ctd\u003e400 mV\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;1MΩ, \u0026lt;100 pF\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;80 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e10\u003csup\u003e6\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eV Hz Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eGeneral specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay (LCD)\u003c\/td\u003e\n\u003ctd\u003e4000 counts, updates 3\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e500 hours minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTemperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-30 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRelative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003eNon-condensing (\u0026lt;10°C)\u003cbr\u003e≤90% RH at 10 °C to 30 °C;\u003cbr\u003e≤75% RH at 30 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 MΩ range\u003cbr\u003e≤80% RH at 10 °C to 30 °C;\u003cbr\u003e≤70% RH at 30 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd\u003e0.1 X (specified accuracy) \/°C (\u0026lt;18 °C or \u0026gt;28 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse protection for current inputs\u003c\/td\u003e\n\u003ctd\u003e440 mA, 1000 V Fast Fuse, Fluke specified part only.\u003cbr\u003e11A, 1000V Fast Fuse, Fluke specified part only.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd\u003e183 x 91 x 49.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e455 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd\u003eIP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1, IEC61010-2-030 CAT III 600 V, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1: Portable EMC Environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eClass A equipment (industrial broadcasting \u0026amp; communication equipment)\u003csup\u003e1\u003c\/sup\u003e\u003cbr\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or\u003cbr\u003euser should take notice of it. This equipment is intended for use in business environments and is not to be\u003cbr\u003eused in homes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hydromatics Limited","offers":[{"title":"Default Title","offer_id":53060065853806,"sku":null,"price":0.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/7812\/1070\/files\/Untitled_5x5in_33.png?v=1765196082","url":"https:\/\/www.hydromaticsea.com\/products\/fluke-15b-digital-multimeter","provider":"Hydromatics Limited","version":"1.0","type":"link"}