{"product_id":"fluke-1555-fc-10-kv-insulation-tester-kit","title":"Fluke 1555 FC 10 kV Insulation Tester Kit","description":"\u003ch2 class=\"features-title\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003eQuickly configure, start and stop tests on the 1555 remotely, a safe distance away from any operating, energized equipment, using\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/content.fluke.com\/promotions\/promo-multi\/fluke-connect\/fluke-connect-insulation-tester\/lp.html\" class=\"ext\" data-extlink=\"\" rel=\"noopener noreferrer\" title=\"\" target=\"_blank\"\u003eFluke Connect\u003csup\u003e®\u003c\/sup\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eand a smart phone\u003c\/li\u003e\n\u003cli\u003eReal time trending gives you easy-to-see visual cues, rather than hard to read, rapidly changing values\u003c\/li\u003e\n\u003cli\u003eReport creation using\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke.com\/en\/search\/fluke\/?query=Fluke+Connect+desktop\"\u003eFluke Connect desktop\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003esaves time and makes test results easier to understand\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/content.fluke.com\/promotions\/promo-multi\/fluke-connect\/fluke-connect-insulation-tester\/lp.html\" class=\"ext\" data-extlink=\"\" rel=\"noopener noreferrer\" title=\"\" target=\"_blank\"\u003eFluke Connect\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003esaves test results to the cloud for analysis and preventive maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct overview: Fluke 1555 FC 10 kV Insulation Tester Kit\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003cp\u003e\u003cstrong\u003eEvaluate the trends, eliminate the doubt\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1555 insulation resistance tester kit offers digital insulation testing up to 10 kV in an industrial strength case, with all the heavy duty leads and clips you need. Plus, the Fluke Connect wireless app performs tests and collects data while you stay a safe distance away.\u003c\/p\u003e\n\u003cp\u003eRemote operation lets you spend as little time as possible in potentially hazardous zones. Real-time trending shows a live graph on your phone, rather than a hard-to-read set of changing values. And you can create reports quickly, using pre-designed templates that you can customize with company logos.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/content.fluke.com\/promotions\/promo-multi\/fluke-connect\/fluke-connect-insulation-tester\/lp.html\" class=\"ext\" data-extlink=\"\" rel=\"noopener noreferrer\" title=\"\" target=\"_blank\"\u003eLearn more\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eFluke insulation testers can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1555 FC 10 kV Insulation Tester Kit\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe tester's accuracy is specified for one year after calibration at operating temperatures of 0°C to 35°C. For operating temperatures outside the range (-20°C to 0°C and 35°C to 50°C), add ±.25% per °C, except on the 20% bands add ±1% per °C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Resistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eTest voltage (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ,\u003cbr\u003e250 kΩ to 5 GΩ\u003cbr\u003e5 GΩ to 50 GΩ\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cbr\u003e500 kΩ to 10 GΩ\u003cbr\u003e10 GΩ to 100 GΩ\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cbr\u003e1 MΩ to 20 GΩ\u003cbr\u003e20 GΩ to 200 GΩ\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cbr\u003e50 GΩ to 500 GΩ\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cbr\u003e5 MΩ to 100 GΩ\u003cbr\u003e100 GΩ to 1 TΩ\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e10000 V\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 MΩ\u003cbr\u003e10 MΩ to 200 GΩ\u003cbr\u003e200 GΩ to 2 TΩ\u003cbr\u003e\u0026gt; 2 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar graph range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation test voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-0%, +10% at 1 mA load current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInduced AC mains current rejection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging rate for capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 seconds per μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge rate for capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 s\/μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLeakage current measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(5% + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCapacitance measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 μF to 15.00 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(15% rdg + 0.03 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTimer\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 99 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution setting\u003c\/td\u003e\n\u003ctd\u003e1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution indication\u003c\/td\u003e\n\u003ctd\u003e1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLive circuit warning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWarning range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 V to 660 V AC\/DC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage accuracy\u003c\/td\u003e\n\u003ctd\u003e±(15% + 2 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware specifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e75 x 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12 V lead-acid rechargeable battery, Yuasa NP2.8-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharger Input (AC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e85 V to 250 V AC 50\/60 Hz 20 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThis Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.7 kg (8.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature (operating)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 50°C (-4°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature (storage)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 65°C (-4°F to 149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e80% to 31°C decreasing linearly to 50% at 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure sealing\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput overload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1: Overvoltage category II, Pollution Degree 2.\u003cbr\u003eIEC 61010-2-030: Measurement 600V CAT IV \/ 1000V CAT III\u003cbr\u003eIEC 61557-1, IEC 61557-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hydromatics Limited","offers":[{"title":"Default Title","offer_id":53060055892334,"sku":null,"price":0.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/7812\/1070\/files\/Untitled_5_x_5_in_32.png?v=1765194257","url":"https:\/\/www.hydromaticsea.com\/products\/fluke-1555-fc-10-kv-insulation-tester-kit","provider":"Hydromatics Limited","version":"1.0","type":"link"}