Skip to content
Now offering free shipping on all orders over Kshs 5,000!
Now offering free shipping on orders over Kshs 5,000!

Fluke 319 True RMS AC/DC Clamp Meter, 1000A, 37mm Jaw, CAT III 600V

Free returns on all eligible orders

You have 30 days to request a return. All sale items are final sale.

Key features

The two models are economic, compact and offer a range of special features:

  • Unique 40A high-precision low current measurement--0.01A high-resolution, 1.6% high-precision measurement
  • The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces
  • The large backlight display facilitates readings in dark environments
  • Starting current (inrush) functionality (319) allows measurement of the starting current of electrical and lighting equipment, for example. (319)
  • Current frequency measurement
  • Precision down to 0.01A and 0.1V
  • 1000A/600A AC/DC current measurement (319/317)
  • 600V AC/DC voltage measurement
  • 4000Ω resistance measurement
  • Continuity beeper
  • Auto off function enhances battery life, meaning the instrument can work when you need it screen store ‘hold’ function for capturing a measurement result on the screen
  • One year warranty

Product overview: Fluke 319 Clamp Meter

The Fluke 319 is designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. These small and rugged clamp meters are ideally suited for current measurements up to 1000 A (319) in tight cable compartments. The Fluke 319 also offers AC/DC current measurements and has a higher resolution for loads below 40 A. In addition to a compact package with a strong feature set, the Fluke 319 also equip with In-rush current and Frequency functions for testing motors, lighting, etc.




Specifications: Fluke 319 Clamp Meter

General specifications
Digital display 6000 count resolution
Low battery Indication Displays a signal when the batteries are below their required voltage
Power source Three AAA IEC LR03 batteries
Clamp opening size 1.45 in (37 mm)
Jaw diameter 1.45 in (37 mm)
Dimensions (L x W x H) 9.21 in x 2.95 in x 1.37 in
(234.0 mm x 75.0 mm x 34.8 mm)
Weight Approximately 13.5 oz (384 g) (batteries included)
Auto range Available in Ohms
Safety CE
EN/IEC 61010-1 and IEC 61010-2-032
Measurement Category: 600V CAT III
319 Electrical specifications
Current AC Range 40.00 A, 600.0 A, 1000 A
Resolution 0.01 A, 0.1 A, 1 A
Accuracy 1.6% ±6 digit (50-60 Hz) {40 A}
2.5% ±8 digit (60-500 Hz) {40 A}
1.5% ±5 digit (50-60 Hz) {600/1000 A}
2.5% ±5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC response rms
Current DC Range 40.00 A, 600.0 A, 1000 A
Resolution 0.01 A, 0.1 A, 1 A
Accuracy 1.6% ±6 digit (40 A)
1.5% ±5 digit (600/1000 A)
Voltage AC Range 600.0 V
Resolution 0.1 V
Accuracy 1.5% ±5 digit (20-500Hz)
AC response rms
Voltage DC Range 600.0 V
Resolution 0.1 V
Accuracy 1% ±4 digit
Resistance Range 400.0 Ω
4000 Ω
Resolution 0.1 Ω
1 Ω
Accuracy 1% ±5 digit
Continuity ≤ 30 Ω
Inrush Integration time 100 ms
Frequency Range 5.0 - 500.0 Hz
Accuracy 0.5% ±5 digit
Trigger Level 10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A
The accuracy specifications aply at 73 °F ±41 °F (23 °C ±5 °C)
Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C.
True rms for ac V and ac A accuracy is specified from 5% to 100% of range.
Environmental specifications
Operating temperature 14°F to 122°F (-10 °C to 50 °C)
Storage temperature -40 °F to 140 °F (-40 °C to 60 °C)
Operating humidity Non-condensing (< 50 °F) (< 10 °C)
90% RH (50 °F to 86 °F) (10 °C to 30 °C)
75% RH (86 °F to 104 °F) (30 °C to 40 °C)
45% RH (104 °F to 122 °F) (40 °C to 50 °C)
(Without condensation)
Operating altitude 1 mile (2000 meters) above mean sea level
Storage altitude 7 miles (12,000 meters) above mean sea level
IP Rating IP40
Vibration requirements Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
Drop test requirements 3 ft (1 m) drop test, six sides, oak floor
EMI, RFI, EMC Instrument unspecified for use in EMC field ≥ 0.1 V/m
Temperature coefficients 0.1x (specified accuracy)/ °C
(<64 °F or > 82° F)
(<18 °C or > 28 °C)
Shipping information

Use this text to share information about your product.

Returns & warranty

Use this text to share information about your product.

Fast Quotes

Get your quotation within 24 hours

Genuine Brands

Authorised distributor for Fluke, Milwaukee, Sick, RS & more

Technical Support

Expert guidance on products & applications

Large Stock Ready

Quick delivery from our Nairobi warehouse

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare