Fluke FEV350 EV Charging Station Analyzer

Free returns on all eligible orders

You have 30 days to request a return. All sale items are final sale.

Key Features

  • Create and push test plans directly from TruTest™ for faster setup
  • Run GFCI trip tests to verify safety performance
  • Capture pass/fail results for quick compliance decisions
  • Automate control pilot (CP) signal checks with waveform analysis
  • Save time with guided workflows and automated sequences

Product overview: Fluke FEV350 EV Charging Station Analyzer

The Fluke FEV350 is a complete solution for safety and performance testing of AC EV charging stations with Type 2 or Type 1 connectors. It is designed for technicians who need to perform and document multiple tests quickly and efficiently without carrying multiple tools. Expert Mode streamlines operation for experienced users by eliminating instructional pop-ups, while Auto-Sequence enables all sub-tests within a measurement function to be run with a single button press. Expanded configuration options further extend compatibility across a wide range of electrical systems and regional requirements, making the FEV350 an adaptable and efficient tool for EVSE testing and reporting.

Available measurements: 

  • PE (protective) earth pre-test to ensure no dangerous voltage is present
  • Visual Inspection
  • 30 Ma Rcd + 6 Ma Rdc-Dd Trip Test
  • Nominal Voltage + Phase Sequence
  • Auto Control Pilot (Cp) with Waveform Analysis
  • Proximity Pilot
  • Error Testing

Supported measurements with compatible Fluke multifunction testers:

  • Earth Bond
  • Insulation
  • Loop/Line Impedance

With TruTest™ software, spend less time processing test results and compiling reports:

  • Easily manage measurement data from EVSE inspections
  • Quickly create inspections and reports
  • Control Pilot waveform analysis with easy pass/fail visuals
  • Compare site data to previous site data to see changes over time
  • Quickly access the latest firmware to update your FEV350
  • Faster setup through TruTest™ bi-directional support
  • Download a free 60-day demo version of TruTest. Purchase a software key to unlock the Lite or Advanced version.

The FEV350 integrates seamlessly with the TruTest™ EV Charging software module for both documentation and reporting. Through wireless Bluetooth® connection, the FEV350 works alongside compatible Fluke multifunction installation testers, providing supporting measurements, wiring configuration diagrams, and information screens. With new bi-directional communication, customized test plans can be created in TruTest™ and pushed directly to the FEV350, reducing setup time and eliminating re-entry of project data. Predetermined test plans and clear pass/fail indications simplify analysis and speed up testing, while full integration with TruTest™ ensures reliable reporting. The FEV350 EV Charging Station Analyzer is designed in accordance with IEC/EN 61851-1 and IEC/HD 60364-7-722.

Specifications: Fluke FEV350 EV Charging Station Analyzer

Test function specifications

The operational error specification reference for digit counts is defined as ±(% of reading + digit counts). The operational error for other specifications that reference a % are defined as the % of the reading unless otherwise specified. The operational error specification reference temperature for all readings is 23 °C ±5K temperature coefficient of 0.1 %/°C.

Test/function Display range Measurement range Operational error Nominal values
PE pre-test
Touch voltage, safe range 50 V AC/DC -50% --
Touch voltage, dangerous range >50 V AC/DC +0% --
Visual inspection See checklist
Earth bond, RLO[1] -- @ >200 mA Itest
Insulation, RINS[1] -- @ 500 V Unom
Loop/Line impedance[1] -- no trip loop
RCD/RDC-DD pre-test
Uf 5V to 110V  -(0 % + 0 digits),
+(10 % + 3 digits)
@ Itest
0.33 x IΔN AC
Re 166 Ω to 3667 Ω -10 % to +15 %
RCD test (IΔN 30 mA)
RCD type A, B/B+, RDC-PD -- @ mains 100 V AC to 253 V AC
RCD trip time with AC, half wave, DC (0°, 180°)
    x0.5 (30 mA) 0 ms to 510 ms ±(2 % + 3 ms)
    x1 (30 mA) TN: 0 ms to 310 ms
TT @120 V: 0 ms to 310 ms TT @230 V: 0 ms to 210 ms
    x5 (30 mA) 0 ms to 50 ms
Ramp current (0°, 180°)
    AC @RCD type B/B+ 12.0 mA to 36.0 mA, 17 steps with
1.5 mA
±1.5 mA
    AC half wave @RCD type A and RCD-PD 7.5 mA to 48.0 mA, 28 steps with
1.5 mA
    DC @RCD type B/B+ 12.0 mA to 66.0 mA, 37 steps with
1.5 mA
Test/function Display range Measurement range Operational error Nominal values
RDC-DD test (IΔN +6 mA EV)
Trip time (0°, 180°) @ mains 100 V AC to 253 V AC
    +3 mA DC 0.000 s to 10.100 s ±(2 % + 3 ms)
    +6 mA DC
    +60 mA DC 0 ms to 310 ms
    +200 mA DC 0 ms to 110 ms
Ramp current (0°, 180°) smooth ramp
2.0 mA to 6.0 mA
±0.6 mA
Mains voltage
L-N, L-PE, N-PE 0 V to 280 V  0V to 253 V ±(3 % + 3 digits) RIN L-N:
>30 MΩ, RIN L-PE:
>10 MΩ,
40 Hz to 70 Hz,
crest factor 2, Vmax peak: 560 V
L-L 0 V to 490 V 0 V to 440 V RIN L-L: >30 MΩ,
40 Hz to 70 Hz,
crest factor 2, Vmax peak: 980 V
Frequency 40.00 Hz to 70.00 Hz ±0.20 Hz --
Phase sequence right, left, none -- voltage imbalance:
<20 % voltage difference between phases,
phase imbalance:
120° ±10°
50 V to 280 V
phase to N
CP signal analysis
Voltage -15.000 V to
15.000 V
-15.000 V to
-2.000 V,
2.000 V to
15.000 V
±0.5 % RIN: 1 MΩ
0.9000 kHz to
1.1000 kHz;
UCP+ >2.000 V,
UCP- <-2.000 V
PWM duty cycle 2.0 % to 98.0 % 3.0 % to 97.0 % ±5 digits
Current indication 0.0 A to 80.0 A -- Based on duty cycle[3]
Frequency 0.9000 kHz to 1.1000 kHz 0.001
CP state indication A, B, C, D -- Based on voltage[2]
x1, x2 -- Based on frequency[2]
Test/function Display range Measurement range Operational error Nominal values
CP state simulation A -- >900  kΩ ±0.2 % --
B Upper level: 4610  Ω
±0.2 %[2]
Nominal level: 2740  Ω
±0.2 %[2]
Lower level: 1870  Ω
±0.2 %[2]
C Upper level: 1723  Ω
±0.2 %[2]
Nominal level: 1300  Ω
±0.2 %[2]
Lower level: 909  Ω
±0.2 %[2]
D Upper level: 448  Ω
±0.2 %[2]
Nominal level: 270  Ω
±0.2 %[2]
Lower level: 140  Ω
±0.2 %[2]
PP state simulation open -- >900  kΩ --
13 A 1500  Ω ±1.5 %[2]
20 A 680  Ω ±1.5 %[2]
32 A 220  Ω ±1.5 %[2]
63 (70) A 100  Ω ±1.5 %2]
Error <60  Ω (56 Ω ±5 %)
Fault simulation PE error (earth fault/PE open) -- -- --
CP error E @ 0 Ω
or 120 Ω
-0  Ω/ +2  Ω,
120  Ω ±1.5 %[2]
Diode short --
Error D
PP voltage measurement
(Type 2 with socket)
0.10 V to 15.00 V ±(1.0 % + 3 digits) RIN: 1 MΩ
Test/function Display range Measurement range Operational error Nominal values
PP resistor measurement
Type 2 with cable (Rc) 50.0 Ω to 499.9 Ω
500  Ω to 5000 Ω
±1.0 % --
Type 1 with cable (S3, R6, R7)
CP resistor measurement (R1) 800  Ω to 1200 Ω ±1.0 % --
[1]   The test requires a multi-function tester (MFT). See the documentation of the MFT for the display range, measurement range, and operational error or accuracy values.
[2]   According to IEC 61851-1.
[3]   According to table A.8 of IEC 61851-1.
General Specifications
Input electrical ratings Φ: 250 V max
Φ: 230/400V max, 50/60 Hz, max 1 A
Internal power consumption 3 W max
Size (H x W x D) ~(263 mm x 123 mm x 63 mm)
~(10.35  in x 4.84 in x 2.48 in), without the TY1 or TY2 plug
Weight ~0.9 kg, without the TY1 or TY2 plug
~1.4 kg, with the TY1 or TY2 plug
Battery 4 x AA/IEC LR6 alkaline or IEC HR6 NiMH
Temperature
Operating -10 °C to 40 °C (14 °F to 104 °F)
Storage -20 °C to 50 °C (-4 °F to 122 °F)
Relative humidity
Operating 10 % to 85 %, 0 °C to 40 °C
(32 °F to 104 °F), non-condensing
Storage up to 95 %
Wireless radio, Bluetooth 5.0
Frequency range 2412 MHz to 2462 MHz
Output power <100 mW
Altitude 3000 m
Safety IEC 61010-1: Pollution Degree 2, IEC 61010-2-030, CAT II 300 V, Protection Class II
Performance IEC 61557-1, IEC 61557-6, IEC 61557-7, IEC 61557-10
Ingress protection IEC 60529: IP40
Shipping information
Returns & warranty
Fast Quotes

Get your quotation within 24 hours

Genuine Brands

Authorised distributor for Fluke, Milwaukee, Sick, RS & more

Technical Support

Expert guidance on products & applications

Large Stock Ready

Quick delivery from our Nairobi warehouse

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare